Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/12780
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Gonzáles Chávez, Salomé | - |
dc.contributor.author | Rosas Martínez, Néstor | - |
dc.creator | Gonzáles Chávez, Salomé | - |
dc.creator | Gonzáles Chávez, Salomé | - |
dc.date.accessioned | 2018-07-25T23:26:55Z | - |
dc.date.available | 2018-07-25T23:26:55Z | - |
dc.date.issued | 2014-06-01 | - |
dc.identifier.citation | Gonzales Chávez, S., & Rosas Martínez, N. (2014). Mejoramiento energético y económico de una refrigeradora doméstica sustituyendo su refrigerante original r12 por otro ecológico - análisis experimental. Revista TECNIA, 24(1), 31. https://doi.org/10.21754/tecnia.v24i1.29 | es |
dc.identifier.issn | 2309-0413 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/12780 | - |
dc.description.abstract | Se demuestra de forma experimental la mejora energética y económica de una refrigeradora tipo doméstica, a partir de solamente sustituir su refrigerante original R-12 (CFC de característica contaminante y degradante de la Capa de Ozono), por otro refrigerante del tipo ecológico (HFC) como el R-134a. Comúnmente se practica el reemplazo de una refrigeradora que usa CFC, por otra unidad nueva que utiliza refrigerante ecológico de origen. Sin embargo, en países en vías de desarrollo el sector residencial mayormente cuenta con refrigeradoras que operan con R-12 y con vida de uso superior a los 10 años, no obstante la existencia de acuerdos internacionales que prohíben su utilización. El experimento consistió en: 1) preparación del equipo de refrigeración (dotación de reguladores de carga en el condensador y evaporador, dosificadores de refrigerante y aceite de lubricación-fluidización e instrumentación), 2) protocolo de mediciones, desarrollo de pruebas de operación con R-12 y con refrigerante ecológico sustituto R-134ª para las diversas combinaciones de carga realizadas durante un amplio periodo de experimentación. La evaluación energética se basa en las comparaciones de los ciclos termodinámicos, balances energéticos, potencias y rendimientos, operando el sistema de refrigeración tanto con R-12 como con R-134a. Como resultados se obtienen que el sistema de refrigeración operando con refrigerante ecológico R-134a frente al refrigerante R-12 de origen, se logra condiciones termodinámicas estables de operación y menor consumo de potencia del compresor, para cualquier condición de carga y en amplios periodos de operación. Por tanto, una de las soluciones más convenientes desde el punto de vista socioeconómico, es la sustitución solamente del refrigerante CFC en la misma refrigeradora usada (antigua), haciendo los ajustes y apropiada dosificación del refrigerante ecológico y del aceite de lubricación-fluidización. | es |
dc.description.abstract | We demonstrate experimentally the energy and economic improvement of a domestic refrigerator, after only replace the original refrigerant R-12 (CFC) on the other ecological refrigerant R-134b (HFC). Commonly a refrigerator using CFC is replaced with new green refrigerator. However, in developing countries the residential sector has mostly refrigerators operating with R-12 and life exceeding 10 years use, despite the existence of international agreements that prohibit their use. As a result we obtain that the refrigerator in evaluating operating with ecological refrigerant, compared with R-12 refrigerant source, stable thermodynamic conditions operation and lower power consumption compressor, for all load conditions and extended periods of operation is achieved. Therefore, one of the most convenient solutions from a socioeconomic view point, it is only replacing CFC refrigerant used in the refrigerator (old), making the appropriate dosage of ecological coolant and lubrication oil-fluidization. | en |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.relation | info:eu-repo/semantics/article | es |
dc.relation.ispartofseries | Volumen;24 | - |
dc.relation.ispartofseries | Número;1 | - |
dc.relation.uri | http://revistas.uni.edu.pe/index.php/tecnia/article/view/29 | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Refrigeración doméstica | es |
dc.subject | Refrigerante CFC | es |
dc.subject | Refrigerante ecológico HFC | es |
dc.title | Mejoramiento energético y económico de una refrigeradora doméstica sustituyendo su refrigerante original r12 por otro ecológico - análisis experimental | es |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.journal | TECNIA | es |
dc.description.peer-review | Revisión por pares | es |
dc.identifier.doi | https://doi.org/10.21754/tecnia.v24i1.29 | es |
dc.contributor.email | salome@uni.edu.pe | es |
Aparece en las colecciones: | Vol. 24 Núm. 1 (2014) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TECNIA_Vol.24-n1-Art. 7.pdf | 294,92 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: