Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/13789
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Nahui Ortíz, Johnny Prudencio | - |
dc.contributor.author | Gamarra Supo, José Luis | - |
dc.contributor.author | Rivera Muñoz, Robert Nigel | - |
dc.creator | Rivera Muñoz, Robert Nigel | - |
dc.creator | Gamarra Supo, José Luis | - |
dc.date.accessioned | 2018-09-18T16:09:22Z | - |
dc.date.available | 2018-09-18T16:09:22Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/13789 | - |
dc.description.abstract | En el presente trabajo de investigación se evalúa y analiza la conveniencia de implementar un sistema de cogeneración para disminuir costos, tomando la relación causa - efecto de las variables: “Sistema de Cogeneración’’ y “Reducción de costos energéticos’’ de una industria textil, encontrándose en la planta ARIS de nuestra investigación que las instalaciones de las que dispone constituyen un relevante centro consumidor de energía en forma de vapor, agua caliente, aceite térmico y energía eléctrica (2MW). ARIS pretende incorporar en sus instalaciones una planta de cogeneración de alta eficiencia, con la finalidad de aprovechar las ventajas que ofrece dicha tecnología tanto a nivel de eficiencia energética como de ahorros económicos, dotando de mayor competitividad a su proceso industrial. Ante tal situación, en la presente investigación, viendo la necesidad de ahorros económicos y cubrir su demanda total de energía eléctrica y ampliación a futuro de la planta textil, se ha realizado un sondeo de alternativas de cogeneración con plantas de distintos tamaños (2 - 3.3 MW) con tecnologías de ciclo simple. El estudio está basado en la comparación de las prestaciones energéticas y económicas respecto a la situación esperada tras una futura ampliación de la planta, de la misma manera se realizó la recopilación de los datos de los consumos vapor y energía cada hora las 24 horas del día durante todo un año de la plata textil, para así poder obtener los gráficos de las curvas monótonas de demandas de consumo de energía Eléctrica y Térmica como también poder visualizar la máxima demanda de consumo de las misma durante todo un año. Utilizando los datos estadísticos de los consumos de vapor y energía eléctrica por hora/día desde el mes de enero al mes de diciembre del 2012 en la empresa Textil “ARIS INDUSTRIAL’’, utilizando el software básico Excel 2010 se determinó la Demanda eléctrica y térmica anual con sus respectivas curvas, siendo estos datos las herramientas empleadas en nuestro trabajo de investigación. | es |
dc.description.abstract | In the present work the efficiency of a cogeneration system to reduce costs is evaluated and analyzed, taking the cause - effect relationship of the variables: "Cogeneration System" and "Reduction of energy costs" of a textile industry, being found in the ARIS plant of our investigation that the facilities available to it constitute a relevant energy center in the form of steam, hot water, thermal oil and electric energy (2MW). ARIS intends to incorporate a high efficiency cogeneration plant in its facilities, in order to take advantage of the advantages offered by this technology in terms of both energy efficiency and economic savings, providing a more competitive industrial process. In view of this situation, in the present investigation, in view of the need for economic savings and to cover its total electric energy demand and future expansion of the textile plant, a survey of cogeneration alternatives with plants of different sizes has been carried out (2 - 3.3 MW) with simple cycle technologies. The study is based on the comparison of the energy and economic benefits in relation to the expected situation after a future expansion of the plant, in the same way the data collection of the consumption of steam and energy was done every hour 24 hours a day during a whole year of the textile silver, to be able to obtain the graphs of consumption demands of Electric and Thermal energy as well as to be able to visualize the maximum demand of consumption of the same during a whole year. Using the statistical data of the consumption of steam and electric energy per hour / day from the month of January to the month of December of 2012 in the company Textile "ARIS INDUSTRIAL", using the basic software Excel 2010 was determined the Electric and thermal demand with their respective curves, these data being the tools used in our research work. | en |
dc.description.uri | Tesis | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Sistema de cogeneración | es |
dc.subject | Demanda térmica | es |
dc.subject | Eficiencia energética | es |
dc.title | Reducción de costos energéticos de una industria textil mediante un sistema de cogeneración | es |
dc.type | info:eu-repo/semantics/masterThesis | es |
thesis.degree.name | Maestro en Ciencias con Mención en Energética | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Mecánica. Unidad de Posgrado | es |
thesis.degree.level | Maestría | es |
thesis.degree.discipline | Maestría en Ciencias con Mención en Energética | es |
thesis.degree.program | Maestría | es |
Aparece en las colecciones: | Maestría |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
gamarra_sj.pdf | 3,66 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: