dc.contributor.authorOrdoñez Huamán, Edwin Abel-
dc.contributor.authorMinaya González, Silene Azucena-
dc.creatorOrdoñez Huamán, Edwin Abel-
dc.creatorMinaya González, Silene Azucena-
dc.date.accessioned2018-10-05T21:59:50Z-
dc.date.available2018-10-05T21:59:50Z-
dc.date.issued2001-12-01-
dc.identifier.citationOrdoñez Huamán, A., & Minaya González, S. (2001). C,B,R, de subrasantes arenosas y limo-arcillosas. TECNIA, 11(2). https://doi.org/10.21754/tecnia.v11i2.522es
dc.identifier.urihttp://hdl.handle.net/20.500.14076/14372-
dc.description.abstractActualmente en el Perú, el diseño de estructuras de pavimentos considera generalmente valores de capacidad de soporte de subrasantes arenosas y limo-arcillosas determinados a partir de ensayos de laboratorio CBR - ASTM D 1883. La metodología utilizada puede no ser adecuadamente aplicada cuando se asume el valor C.B.R. de la sub-rasante relacionado a la densidad seca equivalente al 95% ó 100% de la Máxima Densidad Seca - MDS del ensayo Proctor Modificado. La humedad y la densidad seca natural de los suelos limo-arcillosos tienen una influencia importante en la determinación del C.B.R. como se ha podido comprobar en las pruebas sobre muestras inalteradas y compactadas. Se realizaron comparaciones de valores C.B.R. obtenidos de muestras inalteradas y compactadas considerando el 95% y 100% de la MDS del ensayo Proctor Modificado. Asimismo, se compararon valores de módulos elásticos, utilizando una extensión de la teoría elástica. Los resultados indican que los valores de C.B.R. y módulos elásticos obtenidos en muestras inalteradas son significativamente inferiores a los determinados en muestras compactadas. La práctica ingenieril para la determinación del C.B.R. de la sub-rasante basados en muestras inalteradas es casi no utilizada en el Perú, debido a ello, se presentan fallas prematuras de pavimentos por sub-dimensionamiento en el diseño.es
dc.description.abstractAt the present time in Peru the design of pavement structures generally considers values of bearing capacity ratios of natural subgrade of sandy and silty clay soils, using the CBR laboratory test - ASTM D 1883. The methodology used may not be properly used when the CBR value of natural subgrade is assumed to be related to the dry density equivalent to 95% or 100% of the Maximum Dry Density - MDS of the Modify Proctor Compactation Test. The moisture content and the natural dry density of silty clay soils have an important influence in the CBR value determination as was verified in testing of undisturbed and compacted samples. Comparisons were made from CBR. values obtained from undisturbed and compacted samples considering 95% and 100% of the MDS of the Proctor Modified Compactation Test. Also, were made comparisons of values of elastic modulus, using an extension of the elastic theory. The results indicate that the CBR values and elastic modulus obtained on undisturbed samples are significantly lower than compacted samples. The engineering practice for CBR value determination of subgrade based on undisturbed samples is not used in Peru, because of that premature failures and collapse in pavement structures are produced.en
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.relation.ispartofseriesVolumen;11-
dc.relation.ispartofseriesNúmero;2-
dc.relation.urihttp://revistas.uni.edu.pe/index.php/tecnia/article/view/522es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectPavimentoses
dc.subjectSueloses
dc.titleC,B,R, de subrasantes arenosas y limo-arcillosases
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.journalTECNIAes
dc.description.peer-reviewRevisión por pareses
dc.identifier.doihttps://doi.org/10.21754/tecnia.v11i2.522es
Aparece en las colecciones: Vol. 11 Núm. 2 (2001)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TECNIA_Vol.11-n2-Art.7.pdf9,41 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI