Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/18713
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBarzola Gastelú, Carlos Armando-
dc.contributor.authorTorres Velásquez, Pamela-
dc.creatorTorres Velásquez, Pamela-
dc.date.accessioned2019-10-22T13:38:14Z-
dc.date.available2019-10-22T13:38:14Z-
dc.date.issued2019-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/18713-
dc.description.abstractEl presente trabajo de investigación tiene como objetivo conocer el deterioro del concreto simple y armado con cemento Portland Tipo I por ataque del Cloruro Férrico en solución al 42% ya que muchas estructuras de concreto, como tanques, se encuentran expuestas a este químico por ser usado como parte del tratamiento de potabilización del agua. Para conocer el deterioro se utilizaron probetas de tamaño 4”x8” de concreto simple y concreto armado (con una varilla de 10 cm de largo al centro) de relación a/c = 0.45, 0.50, 0.60 y 0.70 y varillas de acero corrugado de 3/8” de diámetro que fueron sometidas a corrosión acelerada mediante el proceso descrito en la tesis del Ing. José Luis Díaz Lazo titulada “Corrosión del cemento por ataque de Sulfatos”. Luego de culminar con el ensayo de corrosión acelerada se procedió a identificar las variaciones de peso de las probetas respecto a las probetas patrón también se identificaron los valores de las propiedades mecánicas, físicas y químicas de las probetas respecto a las probetas patrón, con la finalidad de conocer el deterioro del concreto. Finalmente, el presente trabajo de investigación podrá ser usada como guía para los constructores que se encuentren trabajando en estructuras expuestas al Cloruro Férrico en solución al 42%, así mismo servirá como guía para los investigadores que deseen profundizar su conocimiento y determinar el deterioro o corrosión del concreto expuesto a este químico.es
dc.description.abstractThe objective of this research work is determine the deterioration of simple concrete and the reinforcement concrete with Portland Type I cement by attack of Ferric Chloride in 42% solution because many concrete structures, such as tanks, are exposed to this chemical by be used as part of the water purification treatment. In order to know the deterioration, It was used pieces of size 4 "x8" of simple concrete and reinforced concrete (with a Corrugated steel rod of 10 centimeters of length into the center) of relation a / c = 0.45, 0.50, 0.60 and 0.70 and corrugated steel rods were used of 3/8 " of diameter that were subjected to accelerated corrosion by the process described in the thesis of Eng. José Luis Díaz Lazo entitled "Corrosion of cement by attack of sulphates." After completing the accelerated corrosion test, we proceeded all of the data to identify the weight variations of the test specimens with respect to the standard specimens; the values of the mechanical, physical and chemical properties of the specimens with respect to the standard specimens, with the purpose to know the deterioration of concrete. Finally, this research work can be used as a guide for builders who are working on structures exposed to Ferric Chloride in 42% solution, also it can be used as a guide for researchers who wish to deepen their knowledge and determine the deterioration or corrosion of the concrete exposed to this chemical.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectConcreto armadoes
dc.subjectCloruro férricoes
dc.subjectDeterioroes
dc.titleDeterioro del concreto armado por ataque del cloruro férricoes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Civiles
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Civiles
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Civiles
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-6087-9702es
renati.author.dni47219504-
renati.advisor.dni10408631-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline732016-
renati.jurorVillegas Martínez, Carlos Alberto-
renati.jurorQuintana Alfaro, Noemi Leopoldina-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.01es
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
torres_vp.pdf4,12 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI