Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/18998
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorCortéz Galindo, Hernán-
dc.contributor.authorGarcía Meneses, Dante Andrés-
dc.creatorGarcía Meneses, Dante Andrés-
dc.date.accessioned2020-02-27T15:23:09Z-
dc.date.available2020-02-27T15:23:09Z-
dc.date.issued2019-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/18998-
dc.description.abstractEl mercado global de edificios inteligentes se tasó en $ 12,371 millones en 2017 y se proyecta que alcance los $ 42,649 millones para 2024. Actualmente los diseños de control de edificios reducen la intervención del hombre mediante el uso de controles horarios preestablecidos u otros controles similares. Por otro lado, el ahorro de energía es una tendencia actual y como ingenieros debemos proporcionar las mejores soluciones para el control de los edificios. El objetivo del presente trabajo es la evaluación de diversas estrategias de control en un edificio y predecir su consumo de energía eléctrica anual utilizando un modelamiento energético mediante los programas Design Builder y Energy Plus. Se evaluó: el uso de variadores de frecuencia en la bomba secundaria de agua helada, en el motor del ventilador de las torres de enfriamiento y en los ventiladores de aire fresco; la optimización de la secuencia de operaciones de chiller respecto a la demanda instantánea; y controles de iluminación de luz natural y presencia. Además, se realizó el diseño de cada estrategia de control para el funcionamiento de los controladores de campo y principal. También, se comparó el ahorro de electricidad con el costo de implementar el sistema de control y se estimó el tiempo de retorno de inversión. Finalmente, se demostró que un diseño de control en edificios proporciona un ahorro de energía mayor al 17% y que el diseño de control en el edificio proporciona un adecuado confort térmico interior para los ocupantes del edificio y un retorno de inversión de 2 años.es
dc.description.abstractThe global smart building market was valued at $ 12,371 million in 2017 and is projected to reach $ 42,649 million by 2024. Currently, building control designs reduce human intervention through the use of pre-established time controls or other similar controls. On the other hand, energy saving is a current trend and as engineers we must provide the best solutions for the control of buildings. The aim of present work is the evaluation of various control strategies in a building and to predict its annual electricity consumption. Energy modeling has been used to calculate energy consumption through the Design Builder and Energy Plus programs. The evaluation includes: frequency drivers in the secondary pump of the chilled water demand circuit, in the fan motor of the cooling towers and in the outdoor air fans; optimization of the sequence of chiller operations with respect to instantaneous demand; and lighting controls for natural light and presence. Furthermore, the design of each control strategy and the sequence of operation of each of the field controllers and the main controller were performed. Also, the electricity savings were compared with the cost of implementing the control system and the time of return on investment was estimated. Finally, we will see that a control design in buildings provides an energy saving greater than 17% and it was demonstrated that the control design in the building provides adequate interior thermal comfort for the occupants of the building and a return on investment of 2 years.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectAire acondicionadoes
dc.subjectAutomatizaciónes
dc.subjectEdificio automatizadoes
dc.titleDiseño de un sistema de automatización para optimizar el consumo de energía en el sistema de aire acondicionado e iluminación de un edificio corporativo de oficinas en Limaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Mecatrónicoes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Mecánicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Mecatrónicaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0009-0002-8528-0109es
renati.author.dni45946565-
renati.advisor.dni06805109-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline713096-
renati.jurorCueva Pacheco, Ronald-
renati.jurorCastro Salguero, Robert Gerardo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.03.02es
Aparece en las colecciones: Ingeniería Mecatrónica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
garcia_md.pdf6,46 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI