Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/21206
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Aquize Palacios, Rubén Darío | - |
dc.contributor.author | Silva Vidal, Osmar Lizandro | - |
dc.creator | Silva Vidal, Osmar Lizandro | - |
dc.date.accessioned | 2021-10-08T16:26:53Z | - |
dc.date.available | 2021-10-08T16:26:53Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/21206 | - |
dc.description.abstract | La Planta de Tratamiento de Aguas Residuales de Pariachi, con un presupuesto de S/. 139 832 531,10, desarrolla un proceso de tratamiento de lodos activados en la modalidad de aeración extendida, con sistema de control de olores, deshidratación de lodos y efluente reutilizable en riego, categoría ECA 3, en la zona de Santa Clara, ATE. Esta fue construida por el consorcio La Gloria, conformado por las empresas Abengoa y GyM; y el suministro del equipamiento, por Schneider Electric Perú en el año 2012. La arquitectura de control implementa el hardware que se requiere en la sala de control, como los servidores HP Proliant y Workstation HP Z400 para el SCADA Vijeo Citect 7.2, el cual adquiere la data vía Modbus TCP/IP, mediante cable de fibra óptica hacia los controladores M340, MicroLogix y S7200. Los controladores M340 tienen bus de campo de Profibus DP y Modbus serial, todos programados en el software del sistema de control Unity Pro 6.0 XL. Los dispositivos de campo configurados como esclavos en la red Profibus DP son analizadores de PH, Redox, oxígeno disuelto y flujómetros Endress+Hauser; y los sistemas eléctricos supervisados, como PowerMeter PM800 y PM700, arrancadores inteligentes Tesys U, HMI Magelis y variadores de velocidad ATV61. La calidad de vida se mejora de 64 125 habitantes directos con la instalación de 9534 conexiones domiciliarias de agua potable y alcantarillado que son tratadas por la Planta de Tratamiento de Aguas Residuales de Pariachi, la cual es operada por Sedapal con un mínimo de operadores y técnicos, puesto que todos los equipos están centralizados y monitoreados en tiempo real. En este documento se introduce al lector al proceso de la Planta de Tratamiento de Aguas Residuales de Pariachi, a las generalidades de control de procesos, al equipamiento y a su respectiva integración en la plataforma de Schneider Electric. | es |
dc.description.abstract | The Pariachi wastewater treatment plant, with a budget of S/. 139 832 531,10, embarks on an activated sludge treatment process in the extended aeration mode, with an odor control system, sludge dehydration and reusable effluent in irrigation, category ECA 3, in the area of Santa Clara, ATE. This was built by the consortium La Gloria, made up of the companies Abengoa and GyM; and the supply of the equipment, by Schneider Electric Peru in 2012. The control architecture implements the hardware that is required in the control room, such as the HP Proliant servers, HP Z400 Workstation for the Vijeo Citect 7.2 SCADA, which acquires the data via Modbus TCP / IP through fiber optic cable to the M340 controllers, MicroLogix and S7200. The M340 controllers have Profibus DP and Modbus serial fieldbus, all programmed in the Unity Pro 6.0 XL control system software. The field devices configured as slaves on the Profibus DP network are PH, Redox, Dissolved Oxygen analyzers and Endress+Hauser flow meters, and supervised electrical systems such as PowerMeter PM800 and PM700, Tesys U smart starters, Magelis HMIs and ATV61 variable speed drives. The quality of life of 64 125 direct inhabitants is improved with the installation of 9534 household connections for drinking water and sewerage, which are treated by the Pariachi wastewater | en |
dc.description.uri | Trabajo de suficiencia profesional | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Proceso de tratamiento de lodos activados | es |
dc.subject | Sistema de automatización | es |
dc.subject | Sistema SCADA | es |
dc.title | Integración del sistema de automatización de una planta de tratamiento de aguas residuales aplicando el sistema SCADA para un proceso aeróbico | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Electrónico | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Eléctrica y Electrónica | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Electrónica | es |
thesis.degree.program | Ingeniería | es |
renati.advisor.orcid | https://orcid.org/0000-0001-7342-3408 | es |
renati.author.dni | 44426546 | - |
renati.advisor.dni | 08590551 | - |
renati.type | http://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 712026 | - |
renati.juror | Lazo Ochoa, Domingo Pedro | - |
renati.juror | Carbonel Olazábal, Daniel Roberto | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.02.01 | es |
Aparece en las colecciones: | Ingeniería Electrónica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
silva_vo.pdf | 7,08 MB | Adobe PDF | Visualizar/Abrir | |
silva_vo(acta).pdf | 113,32 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: