dc.description.abstract | En la ejecución de taludes de carreteras, túneles y obras mineras se presentan ocasionalmente la caída de rocas, las cuales representan un peligro para la seguridad de las personas como también para las estructuras que están a su alrededor. Ante ello, una de las soluciones de estabilización superficial es el sistema de anclajes que consisten en la instalación de pernos para roca y malla galvanizada, con la finalidad de retener la caída de material. Para determinar si la instalación fue correcta, se realiza el ensayo de arranque a los anclajes en campo, que son usados para la validación final del anclaje instalado en un talud, previamente evaluado en su estabilidad general, haciendo uso de programas de la casa Rocscience. El presente trabajo procura aportar conceptos claros acerca de la prueba de arranque a los anclajes, cuya validación no solo se limita a la lectura que se muestra en el manómetro, sino a evaluar el desplazamiento que se da en el anclaje. Con la actualización de la tecnología nuevos conceptos y normas surgen en la teoría de prueba de anclaje como la que encuentra en la norma ASTM 4435 modificada en el 2013. El proyecto “Instalación del sistema de sostenimiento del talud adyacente a la faja CV013 y CV023”, consiste en la instalación permanente de un sistema de protección contra caída de rocas en donde se colocaron pernos de roca consistentes en barras helicoidales de Ø32 mm x 3 m de longitud, con una resistencia a la fluencia en tracción fy= 5200 kg/cm2, además de una malla HR 30 de cocada 8 x 10 cm;estos taludes fueron evaluados bajo los programas Roc Fall V6.0 (evalúa la caída de rocas) , Roc Data V6.0 (evalúa los esfuerzos de la roca) ,Slide V6.0 (evalúa la estabilidad del talud) y Dips V6.0 (evalúa las fallas presentes), el 1% de estos anclajes fueron sometidos a un ensayo de arrancamiento usando como información técnica la norma mencionada líneas arriba. El aporte de la tesis radica en dar recomendaciones en la instalación de anclajes y de las pruebas de ensayo de arrancamiento, con la realización de esos ensayos llegamos a corroborar que el control de calidad en la instalación fue adecuado durante la ejecución del proyecto. | es |
dc.description.abstract | In the execution of slopes for roads, tunnels and mining works occur occasionally the fall of rocks, which represent a hazard for the safety of people as well as the structures that are around them. In view of this, one of the surface stabilization solutions is the anchoring system consisting of the installation of bolts for rock and galvanized mesh. To determine if the installation was correct, the pull-out test is carried out on the anchors in the field, which are used for the final validation of the installed anchor, previously evaluated in general stability, using programs from the Rocscience house. The present work seeks to provide clear concepts about a Pull Out test to the anchors, whose validation is not only limited to the reading shown on the manometer, but to evaluate the displacement that occurs in the anchor. With the update of the technology new concepts and norms arise in the anchor test theory as found in the ASTM 4435 standard modified in 2013. The project "Installation of the slope support system adjacent to the conveyor belt CV013 and CV023", consists on the permanent installation of a protection system against falling rocks where rock bolts consisting of steel bars of Ø32 mm x 3 m in length were placed, with a yield strength in tension fy = 5200 Kg / cm2, in addition to a mesh HR 30 of 8 x 10cm opening; these were evaluated under the programs Roc Fall V6.0 (evaluate the fall of rock), Roc Data V6.0 (evaluate the strength of the rock), Slide V6.0 (evaluate the stability of the slope) and Dips V6.0 (evaluate present failures), 1% of these anchors were subjected to a Pull Out test using ASTM 4435 as technical information. The contribution of the thesis lies in giving recommendations on the installation of anchors and the Pull Out Test, performing of these tests we corroborate that the quality control in the installation was adequate during the execution of the project. | en |
dc.description.uri | Tesis | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Anclajes | es |
dc.subject | Taludes adyacentes | es |
dc.subject | Chancado primario | es |
dc.title | Validación final del sistema de anclajes en taludes adyacentes a las fajas CV013 y CV023 chancado primario Cerro Verde – Arequipa | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Civil | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Civil | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Civil | es |
thesis.degree.program | Ingeniería | es |
renati.author.dni | 47522456 | - |
renati.advisor.dni | 10556931 | - |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 732016 | - |
renati.juror | Atala Abad, César Augusto | - |
renati.juror | Huamán Egoavil, Carlos Ernesto | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.01.01 | es |
Aparece en las colecciones: | Ingeniería Civil |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
lozano_cv.T1.pdf | 4,7 MB | Adobe PDF | Visualizar/Abrir | |
lozano_cv.T2.pdf | 35,42 MB | Adobe PDF | Visualizar/Abrir | |
lozano_cv(acta).pdf | 116,44 kB | Adobe PDF | Visualizar/Abrir |