dc.description.abstractParte fundamental del desarrollo de la tesis “ESTUDIO DEL CONCRETO CON EL CEMENTO PORTLAND TIPO ICO Y ADITIVO IMPERMEABLE” han sido los ensayos del concreto fresco y del concreto endurecido, que se realizaron en el Laboratorio N°1 de ensayos y materiales “Ing. Manuel Gonzales de la Cotera” de la facultad d ingeniería Civil de la Universidad Nacional de Ingeniería. Los primeros ensayos fueron los de los agregados (agregado fino y agregado grueso), los cuales fueron el % de humedad, el PUS y PUC, el % de Abrasión y el % de Absorción, cuyos resultados nos ayudaron a definir las mezclas patrón, mediante el ensayo de máxima compacidad del agregado global. Luego de definir el diseño de mezcla patrón, con a/c=0.4 y el a/c=0.5, se le añadió a cada una de estas, una dosificación de aditivo del 2%, 2.5% y el 3% del aditivo Sika sem impermeabilizante, resultando que por cada relación de agua/cemento 4 diseños. Los ensayos que se realizaron para el concreto fresco fueron 5 los cuales son, de asentamiento, peso unitario, contenido de aire, exudación y el ensayo del tiempo de fragua. Y los ensayos que se realizaron para el concreto endurecidos fueron 3, los cuales fueron de compresión axial, elasticidad estática y absorción de agua. Los resultados nos mostraron que el volumen de vacíos aumenta, en la relación a/c=0.4 hasta un 103% y en la relación a/c=0.5 hasta un 31%%, la absorción aumenta, en la relación a/c=0.4, hasta un 102% y en la relación a/c=0.5 hasta un 73%. Así mismo, y la resistencia a la compresión se reduce, en la relación a/c=0.4 hasta 83% y en la relación a/c=0.5 hasta 86%. De acuerdo a los resultados se observó que el uso del aditivo Sika Sem impermeabilizante en el Cemento Inka Ico, no es viable.es
dc.description.abstractA fundamental part of the development of the thesis "STUDY OF THE CONCRETE WITH THE PORTLAND CEMENT TYPE ICO AND WATERPROOF ADDITIVE" have been the tests of fresh concrete and hardened concrete, which were processed in the Laboratory No. 1 of tests and materials "Ing. Manuel Gonzales de la Cotera ” of the civil engineering faculty of the National Engineering University. he first trials were those of the aggregates (fine aggregate and coarse aggregate), which were% moisture, PUS and PUC,% Abrasion and% Absorption, whose results helped us define the standard mixtures, by the maximum compactness test of the global aggregate. After defining the standard mix design, with a / c = 0.4 and a / c = 0.5, an additive dosage of 2%, 2.5% and 3% of Sika sem additive was added to each of these waterproofing, resulting in each water / cement ratio 4 designs. The tests that were carried out for the fresh concrete were 5 which are, of settlement, unit weight, air content, exudation and the forge time test. And the tests that were performed for hardened concrete were 3, which were axial compression, static elasticity and water absorption. The results showed us that the volume of voids increases, in the ratio a / c = 0.4 up to 103% and in the ratio a / c = 0.5 up to 31 %%, the absorption increases, in the ratio a / c = 0.4 , up to 102% and in the ratio a / c = 0.5 up to 73%. Likewise, and the compressive strength is reduced, in the ratio a / c = 0.4 to 83% and in the ratio a / c = 0.5 to 86%. According to the results it was observed that the use of the Sika Sem waterproofing additive in Inka Ico Cement is not viable.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectConcretoes
dc.subjectCemento Portland tipo Ies
dc.subjectAditivoses
dc.titleEstudio del concreto con el cemento Portland tipo ICO y aditivo impermeablees
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Civiles
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Civiles
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Civiles
thesis.degree.programIngenieríaes
renati.author.dni46383387-
renati.advisor.dni08530040-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline732016-
renati.jurorMoromi Nakata, Isabel-
renati.jurorVillegas Martínez, Carlos Alberto-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.01es
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
nonajulca_rv.pdf4,09 MBAdobe PDFVisualizar/Abrir
nonajulca_rv(acta).pdf116,05 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI