Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Pretell Huamán, Víctor Hugo | - |
dc.contributor.author | Livia Gómez, Denisse Milagros | - |
dc.creator | Livia Gómez, Denisse Milagros | - |
dc.date.accessioned | 2022-03-28T20:03:17Z | - |
dc.date.available | 2022-03-28T20:03:17Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/21776 | - |
dc.description.abstract | Las aguas residuales provenientes de la industria de descarga de buques quimiqueros contienen una gran cantidad de compuestos orgánicos de alto potencial contaminante. TRALSA dentro de su proceso de descarga de buques quimiqueros con Tolueno y Xileno generan residuos de mezcla agua-producto debido al procedimiento empleado en la actualidad. En Tralsa se planteó utilizar procesos avanzados de oxidación para dar tratamiento a sus aguas residuales contaminadas que se generan en las descargas de buques. Estos procesos son aquellos que implican la generación de radicales hidroxilo (°OH) en cantidades suficientes como para degradar la materia orgánica presente en un efluente, tal es el caso del proceso Fenton. Inicialmente se caracterizó una muestra típica de aguas residuales en un laboratorio hallando una DQO de 476 mg/L y DBO5 de 220.3 mg/L, luego se aplicó Fenton a temperatura ambiente con diferentes relaciones de Fe2+/H2O2 (1:1, 1:3, 1:5, 1:7, 1:10, 1:15, 1:20, 1:25, 1:30, 1:40), utilizando un tiempo de contacto de 45 min, pH igual a 3.5, se dejó en reposo las muestras para finalmente pasarlas a través de un filtro y enviarlas nuevamente al laboratorio. Con los resultados se obtuvo un DQO de 36 mg/L y DBO5 de 15.1 mg/L, con ello se estableció como dosificación optima la relación de 1:20 (Fe2+/H2O2). Finalmente las condiciones de trabajo para el sistema de tratamiento a estas aguas fueron una relación molar de 1:20 (Fe2+/H2O2), tiempo de contacto de 45 min, pH igual a 3.5, muestra típica de 476 mg/L de DQO, 220.3 mg/L de DBO5 y a temperatura ambiente con la que se consigue la remoción del 92.4% de la materia orgánica a escala de laboratorio y un 89.3% a escala industrial, dando cumplimiento a la normativa Decreto Supremo N° 037-2008-PCM, Límites Máximos Permisibles de efluentes Líquidos para el Subsector Hidrocarburos. | es |
dc.description.abstract | The wastewater from the chemical tanker unloading industry contains a large quantity of organic compounds with a high polluting potential. TRALSA, in its process of unloading chemical tankers with Toluene and Xylene, generates waste from the water-product mixture due to the procedure currently used. In Tralsa, it was proposed to use advanced oxidation processes to treat its contaminated wastewater that is generated in ship discharges. These processes are those that involve the generation of hydroxyl radicals (°OH) in sufficient quantities to degrade the organic matter present in an effluent, such is the case of the Fenton process. Initially, a typical wastewater sample was characterized in a laboratory, finding a COD of 476 mg/L and BOD5 of 220.3 mg/L, then Fenton was applied at room temperature with different ratios of Fe2+/ H2O2 (1: 1, 1: 3 , 1: 5, 1: 7, 1:10, 1:15, 1:20, 1:25, 1:30, 1:40), using a contact time of 45 min, pH equal to 3.5, it was left the samples at rest to finally pass them through a filter and send them back to the laboratory. With the results, a COD of 36 mg/L and BOD5 of 15.1 mg/L were obtained, with this, the ratio of 1:20 (Fe2+/ H2O2) was established as the optimal dosage. Finally, the working conditions for the treatment system for these waters were a molar ratio of 1:20 (Fe2+/ H2O2), contact time of 45 min, pH equal to 3.5, typical sample of 476 mg/L of COD, 220.3 mg/L of BOD5 and at room temperature with which the removal of 92.4% of the organic matter on a laboratory scale and 89.3% on an industrial scale is achieved, in compliance with the regulations Supreme Decree No. 037-2008-PCM, Limits Maximum Allowable Liquid Effluents for the Hydrocarbons Subsector. | en |
dc.description.uri | Tesis | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Tratamiento de aguas residuales | es |
dc.subject | Procesos Fenton | es |
dc.subject | Contaminación | es |
dc.title | Aplicación del proceso fenton en el tratamiento de aguas residuales de origen de descarga de buques tanques quimiqueros | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Petroquímico | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería de Petróleo, Gas Natural y Petroquímica | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Petroquímica | es |
thesis.degree.program | Ingeniería | es |
renati.advisor.orcid | https://orcid.org/0000-0002-3564-5381 | es |
renati.author.dni | 70063862 | - |
renati.advisor.dni | 08989157 | - |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 724086 | - |
renati.juror | Quispe Ascencio, Virginia Ignacia | - |
renati.juror | Minaya Ames, Carlos Enrique | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.07.03 | es |
Aparece en las colecciones: | Ingeniería Petroquímica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
livia_gd.pdf | 4,28 MB | Adobe PDF | Visualizar/Abrir | |
livia_gd(acta).pdf | 126 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: