Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/21784
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorFurukawa Fukuda, Roberto Sumiyoshi-
dc.contributor.authorMuncivay Gavidia, Luis Alberto-
dc.creatorMuncivay Gavidia, Luis Alberto-
dc.date.accessioned2022-04-04T15:44:55Z-
dc.date.available2022-04-04T15:44:55Z-
dc.date.issued2021-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/21784-
dc.description.abstractEl presente Trabajo de Suficiencia Profesional se refiere a la problemática para transmitir mayor potencia eléctrica en los sistemas de utilización de líneas de media tensión hasta 22.9 kV existentes o de planeamientos futuros, su uso es en el sector industrial, agro-industrial, turístico y minero; son dinámicas, es decir en el tiempo aumentan su productividad y requieren de mayores potencias, obligándose en el caso de las existentes a proyectar una línea nueva o utilizar grupos electrógenos, el caso de una nueva línea requiere de muchos permisos y de la aprobación de propietarios de terrenos que no autorizan el permiso de servidumbre y en el caso de los grupos electrógenos son los altos costos de combustibles y la contaminación ambiental; en ese sentido el objetivo de la investigación fue, la evaluación de líneas de media tensión basados en los sistemas flexibles de transmisión de corriente alterna para incrementar la transmisión de mayor potencia eléctrica, estos sistemas flexibles denominados FACTS son controladores electrónicos de alta potencia para la regulación de flujos y voltajes en líneas de corriente alterna. Para la comprobación de una mayor transmisión de potencia se realizaron simulaciones de flujos de potencia con el programa Digsilent, utilizando como unidad de análisis la línea existente de 37.82 Km de longitud Catac-Conococha en el nivel de 13.8/22.9 kV, los resultados arrojaron que la caída de tensión en la línea hasta 580 kW en el centro de carga estaba en el límite del 5 %, por lo que se recomienda la utilización de los FACTS en soluciones de incrementos de transmisión de potencias.es
dc.description.abstractIn this research professional sufficiency refers to the problem of transmitting greater electrical power in the systems of use of medium voltage lines up to 22.9 kV existing or future planning, its use is in the industrial, agro-industrial, tourist and mining sectors ; They are dynamic, that is, over time, they increase their productivity and require greater powers, forcing in the case of existing ones to design a new line or use generator sets, the case of a new line requires many permits and the approval of owners of lands that do not authorize the easement permit and in the case of generators are high fuel costs and environmental pollution; In this sense, the objective of the research was the evaluation of medium voltage lines based on flexible alternating current transmission systems to increase the transmission of greater electrical power, these flexible systems called FACTS are high-power electronic controllers for regulation of flows and voltages in alternating current lines. To verify greater power transmission, simulations of power flows were carried out with the Digsilent program, using the existing 37.82 km long Catac-Conococha line as a unit of analysis at the level of 13.8 / 22.9 kV, the results showed that the voltage drop in the line up to 580 kW at the load center was in the limit of 5%, so it is recommended to use the FACTS in solutions of increasing power transmission.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectSistemas eléctricos de potenciaes
dc.subjectLíneas de media tensiónes
dc.subjectTransmisión de corriente alternaes
dc.subjectPotencia eléctricaes
dc.titleEvaluación de líneas de media tensión para transmitir mayor potencia basado en el sistema flexible de transmisión en corriente alternaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Mecánico Electricistaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Mecánicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Mecánica-Eléctricaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0003-0514-1817es
renati.author.dni17919391-
renati.advisor.dni41787019-
renati.typehttp://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline713076-
renati.jurorAbregú Leandro, Edwin Asención-
renati.jurorTarazona Bermúdez, Bernabé Alberto-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.03.02es
Aparece en las colecciones: Ingeniería Mecánica y Electrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
muncivay_gl.pdf5,53 MBAdobe PDFVisualizar/Abrir
muncivay_gl(acta).pdf83,4 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI