dc.description.abstractLa presente investigación evaluó el efecto de la variación del tiempo de retención hidráulico (HRT) de 15, 12 10, 8, 6 y 4 horas en un biodigestor, denominado comercialmente, de 600 litros para el tratamiento de aguas residuales de origen doméstico. En un HRT de 15 horas se obtuvo una remoción promedio de 41.5% en DBO, 50% de remoción en DQO, 83.1% de remoción en turbiedad y 100% en sólidos sedimentables. En un HRT de 12 horas se obtuvo una remoción promedio de 33.2% en DBO, 37.2% de remoción en DQO, 80.7% de remoción en turbiedad y 100% en sólidos sedimentables. En un HRT de 10 horas se obtuvo una remoción promedio de 26.6% en DBO, 38.7% de remoción en DQO, 77.56% de remoción en turbiedad y 100% en sólidos sedimentables. En un HRT de 8 horas se obtuvo una remoción promedio de 19.67% en DBO, 42.19% de remoción en DQO, 75.31% de remoción en turbiedad y 100% en sólidos sedimentables. En un HRT de 6 horas se obtuvo una remoción promedio de 21.99% en DBO, 19.78% de remoción en DQO, 62% de remoción en turbiedad y 96.3% en sólidos sedimentables. En un HRT de 4 horas se obtuvo una remoción promedio de 32.95% en DBO, 28.45% de remoción en DQO, 35% de remoción en turbiedad 87.7% en sólidos sedimentables. Según la evaluación se obtuvieron los mejores resultados de remoción de DQO y DBO a un HRT de 15h. Sobre el soporte biológico constituido de aros PET, poseen un área superficial promedio de 73.38 m2/m3 y en promedio albergar 17.36 g de biomasa. Por otra parte, los lodos generados están conformados predominantemente por partículas orgánicas en un 70%, y la producción varia de en función del caudal y otros factores, su altura influye notablemente en la remoción de parámetros como sólidos totales, sólidos disueltos, sólidos suspendidos y sólidos volátiles.es
dc.description.abstractThe present research studied the effect of the variation of the hydraulic retention time (HRT) of 15, 12, 10, 8, 6 and 4 hours of a biodigester, commercially named, of 600 liters for the treatment of domestic wastewater. For an HRT of 15 hours, an average removal of 41.5% was obtained for BOD, 50% removal for COD, 83.1% removal in turbidity and 100% in settling solids. For an HRT of 12 hours, an average removal of 33.2% for BOD, 37.2% removal for COD, 80.7% removal in turbidity and 100% in settling solids was obtained. For an HRT of 10 hours, an average removal of 26.6% was obtained for BOD, 38.7% removal for COD, 77.56% removal in turbidity and 100% in settling solids. For an HRT of 8 hours, an average removal of 19.67% was obtained for BOD, 42.19% removal for COD, 75.31% removal in turbidity and 100% in settling solids. For an HRT of 6 hours, an average removal of 21.99% was obtained for BOD, 19.78% removal for COD, 62% removal in turbidity and 96.3% in settling solids. For an HRT of 4 hours an average removal of 32.95% was obtained for BOD, 28.45% removal for COD, 35% removal in turbidity 87.7% in settling solids. According to the evaluation, the best COD and BOD removal results were obtained at an HRT of 15h. On the biological support made up of PET rings, they have an average surface area of 73.38 m2/m3 and on average house 17.36 g of biomass. On the other hand, the generated sludge is predominantly made up of 70% organic particles, and the production varies depending on the flow and other factors, its height notably influences the removal of parameters such as total solids, dissolved solids, suspended solids and volatile solids.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectBiodigestoreses
dc.subjectRetención hidráulicoes
dc.subjectSistema de tratamientoes
dc.titleEvaluación del tiempo de retención hidráulico en un biodigestor como sistema de tratamientoes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-6140-4266es
renati.author.dni72604438-
renati.advisor.dni10040514-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorSalazar Gavelán, Roger Edmundo-
renati.jurorRosasco Gerkes, Otto Bruno-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
teran_sj.pdf4,47 MBAdobe PDFVisualizar/Abrir
teran_sj(acta).pdf108,49 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI