dc.description.abstractEn la presente investigación se evaluó la reducción de coliformes termotolerantes en dos sistemas de filtración en serie, ambos sistemas en paralelo constan cada una de dos filtros, el primero de lecho convencional y el segundo de lecho reducido; la primera tiene una configuración ascendente ­ descendente y la segunda ascendente-ascendente. La investigación se realizó para las condiciones ambientales de la ciudad de lima entre los meses de agosto del 2018 y abril del 2019. Los sistemas fueron usados para tratar el efluente de un reactor anaerobio de manto de lodos de flujo ascendente, tipo tanque séptico (UASB-TS). Las dimensiones de los filtros eran de 1.5 m de altura por 6.2 cm de diámetro interno; en todo el periodo de investigación se evaluaron los sistemas con 4 tasas de: 33.4 m3/m2. día, 19.1 m3/m2. día, 9.5 m3/m2. día y 4.8 m3/m2. día. Se evaluó principalmente la reducción de coliformes termotolerantes y adicionalmente se evaluaron algunos parámetros fisicoquímicos y sólidos suspendidos totales (SST). Los resultados obtenidos en reducción de coliformes termotolerantes para cada tasa fueron bajos, sin embargo, los mejores resultados se dieron en las tasas de 19.1 m3/m2. día y 9.5 m3/m2. día, llegando a una reducción máxima de 95% (1.3 unidades logarítmicas) con el primer filtro del sistema 1 y una reducción promedio de 76.51% (0.63 unidades logarítmicas) para el efluente final. Para el sistema 2 se encontró una reducción máxima de 89% (0.96 unidades logarítmicas) con una reducción promedio de 73.96% (0.58 unidades logarítmicas) para el efluente final. Los primeros filtros de cada sistema obtuvieron carreras de 7 días, 9 días y 17 días para las tasas de 33.4 m3/m2. día, 19.1 m3/m2. día y 9.5 m3/m2. día respectivamente. Para el segundo filtro del sistema 1 se obtuvieron carreras de 6 días, 7 días y 13 días para las tasas de 33.4 m3/m2. día, 19.1 m3/m2. día y 9.5 m3/m2. día respectivamente; y para el segundo filtro del sistema 2 se obtuvieron carreras de 17 días, 21 días y 34 días para las tasas de 33.4 m3/m2. día, 19.1 m3/m2. día y 9.5 m3/m2. día respectivamente.es
dc.description.abstractIn the present investigation the reduction of thermotolerant coliforms in two series filtration systems was evaluated, both systems in parallel consist of each of two filters, the first of conventional bed and the second of reduced bed; the first has an ascending-descending configuration and the second ascending­ ascending. The investigation was carried out for the environmental conditions of the city of Lima between the months of August 2018 and April 2019. The systems used to treat the effluent from an anaerobic reactor of upflow sludge mantle, septic tank type (UASB-TS). The dimensions of the filters were 1.5 m high by 6.2 cm interna! diameter; In the entire investigation period, the systems were evaluated with 4 rates of: 33.4 m3 / m2. day, 19.1 m3 / m2. day, 9.5 m3 / m2. day and 4.8 m3 / m2. day. The reduction of thermotolerant coliforms was mainly evaluated and some total suspended physicochemical and dangerous parameters (SST) were also evaluated. The results obtained in the reduction of thermotolerant coliforms for each rate were low, however, the best results were obtained at the rates of 19.1 m3 / m2. day and 9.5 m3 / m2. day, reaching a maximum reduction of 95% (1.3 logarithmic units) with the first filter of system 1 and an average reduction of 76.51% (0.63 logarithmic units) for the final effluent. For system 2 there is a maximum reduction of 89% (0.96 logarithmic units) with an average reduction of 73.96% (0.58 logarithmic units) for the final effluent. The first filters of each system obtained 7-day, 9-day and 17-day runs for the rates of 33.4 m3 / m2. day, 19.1 m3 / m2. day and 9.5 m3 / m2. day respectively. For the second filter of system 1, 6-day, 7-day and 13-day runs were obtained for rates of 33.4 m3 / m2. day, 19.1 m3 / m2. day and 9.5 m3 / m2. day respectively; and for the second filter of system 2 they obtained races of 17 days, 21 days and 34 days for the rates of 33.4 m3 / m2 day, 19.1 m3 / m2. day and 9.5 m3 / m2. day respectively.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectFiltros de arenaes
dc.subjectColiformes termotoleranteses
dc.titleReducción de coliformes termotolerantes por filtros de arena en serie de flujo ascendentees
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0001-9020-8232es
renati.author.dni47019231-
renati.advisor.dni10742262-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorSalazar Gavelán, Roger Edmundo-
renati.jurorYaya Beas, Rosa Elena-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
rojas_tj.pdf129,53 MBAdobe PDFVisualizar/Abrir
rojas_tj(acta).pdf307,06 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI