Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/2185
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVidalón Gálvez, José Andrés-
dc.contributor.authorHeredia Cáceres, María Lourdes-
dc.creatorHeredia Cáceres, María Lourdes-
dc.date.accessioned2016-09-20T22:59:17Z-
dc.date.available2016-09-20T22:59:17Z-
dc.date.issued2015-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/2185-
dc.description.abstractEl agua es un recurso natural imprescindible para el desarrollo de la vida en todas sus manifestaciones, es un recurso de gran valor para la mayoría de los procesos productivos. Pero también es un recurso agotable. La Unidad Minera Pierina MBM, que se encuentra ubicada en la provincia de Huaraz, región Ancash cuyas operaciones son a tajo abierto. Tiene un compromiso ambiental para con las comunidades aledañas, contemplado en su Política Ambiental, de esta manera asegurar la entrega de agua a las comunidades en la calidad y cantidad comprometidas. La Planta de Tratamiento de Agua procesa el agua de mina obtenida por bombeo de los pozos de desaguado del fondo del tajo, las aguas captadas por los taladros horizontales y cualquier filtración o afloramiento de la zona. Estas aguas luego de su tratamiento son captadas por las comunidades, cuyo uso es para riego de vegetales y bebida de animales, el exceso de agua es aprovechada para el riego de vías y accesos dentro de las operaciones mineras. El sistema de tratamiento es a través de una neutralización mediante la dosificación de lechada de cal. Con la actualización y publicación de la norma referente a los Límites Máximos Permisibles (LMP), el D.S. N° 010-2010-MINAM, se incluye el monitoreo de cadmio (II) y otros metales. Según esta norma el valor de la concentración de cadmio total (II) debe ser de 0.05 mg/L, pero con el proceso mencionado anteriormente sólo llega a remover hasta un máximo de 0.1 mg/L de cadmio total (II). La característica principal del agua neutralizada obtenida en la Planta de Tratamiento de Agua es el valor de la concentración de cadmio total (II) el cual supera el límite máximo permisible de descarga, condición tal que la hace imposible de poder ser descargada a cursos de agua que utilizan las comunidades. Es por ello que se evalúa la elección del reactivo Secuestrante TMT que es una sal trisódica, Trimercapto-S-Triazina como una alternativa de tratamiento para su utilización en la Planta de Tratamiento de Agua. Logrando valores de concentración de descarga del cadmio total (II) menores a 0.05 mg/L cumpliendo con el D.S. N° 010-2010-MINAM.es
dc.description.abstractWater is esencial for the development of life in all its manifestations; it is a natural and valuable resource for most production processes. But it is also an exhaustible resource. Pierina MBM Minning Unit, which is located in the province of Huaraz, Ancash region whose operations are open pit. It has an enrironmental commitment to the surrounding communities, referred to in its Environmental Policy, thus ensuring the delivery of water to communities engaged in quality and quantity. The Water Treatment Plant processes the mine water obtained by pumping wells drained the bottom of the pit, water drawn by horizontal drilling and any leak or outcropping in the area. These water treatment then are picked up by the communities, whose use is for irrigation of plants and animals drink, excess water is utilized for irrigation and access roads within the mining operations. The treatment system is through neutralization by lime slurry dosage. By updating and publication of the rule concerning the maximum permissible limits (LMP), the D.S. N° 010-2010-MINAM, monitoring of cadmium (II) and other metals are included. According to this standard the value of the total concentration of cadmium (II) should be from 0.05 mg/L, but with the aforementioned process remove only reaches up to 0.1 mg/L total cadmium (II). The main feature of neutralized water obtained in the Water Treatment Plant is the value of the concentration of total cadmium (II) which exceeds the maximum permissible limit of discharge condition such that makes it impossible to be discharged into waterways using communities. That is why the choice of reagent sequestering TMT which is a trisodium salt, trimercapto-S-triazine as an alternative treatment for use in the treatment plant water is evaluated. Obtaining values discharge concentration of total cadmium (II) 0.005 mg / L complying with the D.S. N° 010-2010-MINAM.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectOperaciones minerases
dc.subjectTratamiento de aguas ácidases
dc.subjectRemoción de Cadmioes
dc.subjectAnálisis de resultadoses
dc.titleRemoción de cadmio de aguas ácidas de mina utilizando un reactivo secuestrantees
dc.typeinfo:eu-repo/semantics/masterThesises
thesis.degree.nameMaestro en Ciencias con Mención en Minería y Medio Ambientees
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Geológica, Minera y Metalúrgica. Unidad de Posgradoes
thesis.degree.levelMaestríaes
thesis.degree.disciplineMaestría en Ciencias con Mención en Minería y Medio Ambientees
thesis.degree.programMaestríaes
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
heredia_cm.pdf2,87 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI