Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/21885
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSalazar Gavelán, Roger Edmundo-
dc.contributor.authorZavala Delgadillo, Lionel Igor-
dc.creatorZavala Delgadillo, Lionel Igor-
dc.date.accessioned2022-04-25T19:50:31Z-
dc.date.available2022-04-25T19:50:31Z-
dc.date.issued2020-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/21885-
dc.description.abstractEl presente trabajo consiste en la descripción de los sistemas existentes de saneamiento básico, análisis de las causas y efectos encontrados en la población de la COMUNIDAD NATIVA DE NUEVO MUNDO. En el año base la población es de 893 habitantes. Para un correcto planteamiento técnico del proyecto, se desarrolló el estudio de fuentes y el estudio de calidad de agua, dichos estudios determinaron la factibilidad del acceso al líquido elemento a través del pozo perforado proyectado y los manantes de ladera: Miguel, Antonio y Reynaldo. Como fuentes seleccionadas. El sistema de abastecimiento de agua potable proyectado, contempla tres sistemas hidráulicos independientes, denominados: Sistema Nuevo Mundo, Sistema Selva Verde I y Sistema Selva Verde 11. Para la proyección de la población a lo largo del periodo óptimo de diseño (20 años) se seleccionó una tasa de crecimiento poblacional aritmético de 3.30 %, para todos los sistemas. El sistema nuevo mundo, utilizará el agua del manante de ladera Miguel, por medio de una estructura de captación que a su vez hará la función de cisterna. El agua se transportará al reservorio elevado proyectado (REP-1) de 30 m3 por medio de una tubería de impulsión de HOPE de 90 mm de diámetro. A su vez el agua bombeada del pozo perforado proyectado será impulsada a través de una tubería de HOPE de 75 mm de diámetro al reservorio elevado proyectado (REP- 2) de 15 m3. El sistema selva verde I, utilizará el agua del manante de ladera Antonio, por medio de una estructura de captación que a su vez hará la función de cisterna. El agua se transportará al reservorio elevado proyectado (REP-3) de 8 m3 por medio de una tubería de impulsión de HOPE de 50 mm de diámetro. El sistema selva verde II, utilizará el agua del manante de ladera Reynaldo, por medio de una estructura de captación que a su vez hará función de reservorio, de donde por gravedad el agua será distribuida a la red proyectada. El modelamiento hidráulico de las redes de distribución, se realizaron en un programa de cómputo teniendo en cuenta las recomendaciones técnicas de la normativa vigente.es
dc.description.abstractThis report consists of the description of the existing basic sanitation systems, analysis of the causes and effects found in the population of the NATIVE COMMUNITY OF NUEVO MUNDO, which for the base year has a population of 893 inhabitants. For a correct technical approach to the project, the source study and the water quality study were developed, these studies determined the feasibility of access to the liquid element through the projected drilled well and the hillside springs: Miguel, Antonio and Reynaldo. As selected sources. The projected drinking water supply system includes three independent hydraulic systems, called the Nuevo Mundo System, the Selva Verde I System and the Selva Verde II System. For the projection of the population throughout the optima! design period (20 years), an arithmetic population growth rate of 3.30% was selected for all systems. The new world system will use the water from the Miguel hill spring, through a catchment structure that in tum will act as a cistern. The water will be transported to the projected elevated reservoir (REP-1) of 30 m3 by means of a 90 mm diameter HDPE impulsion pipe. In tum, the water pumped from the projected drilled well will be driven through a 75 mm diameter HOPE pipe to the projected 15 m3 elevated reservoir (REP-2). The green jungle system I will use the water from the Antonio hill spring, through a collection structure that will in tum act as a cistern. The water will be transported to the projected elevated reservoir (REP-3) of 8 m3 by means of a 50 mm diameter HOPE impulsion pipe. The Selva Verde II system will use the water from the Reynaldo hillside spring, by means of a catchment structure that in tum will function as a reservoir, from where the water will be distributed by gravity to the projected network. The hydraulic modeling of the distribution networks was carried out in a computer program taking into account the technical recommendations of the current regulations.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectSaneamiento básicoes
dc.subjectServicios de abastecimiento de aguaes
dc.subjectServicios de aguaes
dc.titleMejoramiento y ampliación del servicio de saneamiento básico, agua y desagüe en la CC.NN. de Nuevo Mundo y anexo Selva Verde del distrito de Megantoni - La Convención - Cuscoes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0009-0002-4663-4888es
renati.author.dni42748345-
renati.advisor.dni07577557-
renati.typehttp://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorRosasco Gerkes, Otto Bruno-
renati.jurorZapata Payco, Arturo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
zavala_dl.pdf14,77 MBAdobe PDFVisualizar/Abrir
zavala_d,l(acta).pdf296,5 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI