Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/21898
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Maldonado Yactayo, Víctor Antonio | - |
dc.contributor.author | Porras Arrieta, Luis Eduardo | - |
dc.creator | Porras Arrieta, Luis Eduardo | - |
dc.date.accessioned | 2022-04-25T22:32:51Z | - |
dc.date.available | 2022-04-25T22:32:51Z | - |
dc.date.issued | 2020 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/21898 | - |
dc.description.abstract | La presente investigación tiene como fin determinar la eficiencia del pasto Vetiver como removedor de arsénico inorgánico en aguas destinadas al consumo humano, mediante el montaje de un piloto pequeño (unidad de tratamiento) y la comparación de las concentraciones de arsénico del afluente y efluente de dicho piloto. Se estableció un diseño preliminar del piloto de investigación y condiciones de operación, designando caudales de 8; 4; 2 y 1 mL/s asociados a tiempos de retención aproximados de 0,75; 1,50; 3,00 y 6,00 días respectivamente, formando así las rondas de tratamiento Nº 1, Nº 2, Nº 3 y Nº 4. El piloto de investigación está compuesto por dos filas (A y B) de cuatro cilindros de plástico, donde ambas filas tienen el mismo afluente. Los cilindros de cada fila están conectados en serie y en cada uno se alberga cuatro grupos de esquejes de pasto Vetiver. Se realizó el monitoreo de cada ronda de tratamiento, desde el inicio de operación hasta la culminación con la toma de muestras de los efluentes. Los resultados mostraron que la mayor remoción de arsénico es del 77,39 % para la fila A y 98,23 % para la fila B. Ambos resultados se obtuvieron cuando el piloto operaba a 2 mL/s en ambas filas. De manera general, el piloto operó mejor en la ronda de tratamiento Nº 3. Por último, se simularon otros escenarios tomando en cuenta el grado de remoción de arsénico inorgánico requerido y el diseño final del piloto, estableciendo condiciones definidas de operación y mantenimiento. | es |
dc.description.abstract | The purpose of this research is to determine the efficiency of Vetiver grass as an inorganic arsenic remover in waters determined for human consumption, by assembling a small pilot (treatment unit) and comparing the arsenic concentrations of the tributary and effluent of said pilot. A prliminary design of the research pilot and operating- conditions was established, designating flows of 8; 4; 2 and 1 mL/s associated with retention times of approximately 0,75; 1,50; 3,00 and 6,00 days respectively, thus forming the treatment rounds Nº 1, Nº 2, Nº 3 and Nº 4. The research pilot is composed of two rows (A and B) of four plastic cylinders, where both rows have the same tributary. The cylinders in each row are connected in series and each group houses four groups of Vetiver grass cuttings. The monitoring of each round of treatment was carried out, from the beginning of the operation until the culmination with the sampling of the effluents. The results that obtained the highest arsenic removal are 77,39 % for row A and 98,23 % for row B. Both results were obtained when the pilot operated at 2 mL/s in both rows. In general, the pilot operated better in treatment round Nº 3. Finally, other changes were simulated taking into account the degree of inorganic arsenic removal required and the final design of the pilot, establishing defined operating and maintenance conditions. | en |
dc.description.uri | Tesis | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Remoción de arsénico | es |
dc.subject | Tratamiento del agua | es |
dc.subject | Chrysopogon Zizanioides L. (Vetiver) | es |
dc.title | Eficiencia de la especie vegetal Chrysopogon Zizanioides L. (Vetiver) en la remoción de arsénico inorgánico en aguas para consumo humano | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Sanitario | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Ambiental | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Sanitaria | es |
thesis.degree.program | Ingeniería | es |
renati.author.dni | 72489128 | - |
renati.advisor.dni | 06604395 | - |
renati.type | http://purl.org/pe-repo/renati/type#tesis | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 733016 | - |
renati.juror | Rosasco Gerkes, Otto Bruno | - |
renati.juror | Huaman Prieto, Veronica Bertha | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.11.02 | es |
Aparece en las colecciones: | Ingeniería Sanitaria |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
porras_al.pdf | 16,19 MB | Adobe PDF | Visualizar/Abrir | |
porras_al(acta).pdf | 104,08 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: