Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/22158
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Sinchi Yupanqui, Francisco Edilberto | - |
dc.contributor.author | Ayala Cárdenas, Santos Eugenio | - |
dc.creator | Ayala Cárdenas, Santos Eugenio | - |
dc.date.accessioned | 2022-05-27T19:46:19Z | - |
dc.date.available | 2022-05-27T19:46:19Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/22158 | - |
dc.description.abstract | La contaminación del aire al interior de un edificio de oficinas, es la causa de múltiples problemas de salud, que se manifiesta desde una fatiga o molestia, hasta síntomas compatibles con alergias, infecciones y cáncer. La calidad del aire dentro de un edificio de oficinas, es importante porque está relacionado con el bienestar, confort y productividad de los ocupantes. Depende de una serie de factores, como la calidad del aire del exterior, el diseño del sistema de ventilación, las condiciones de operación y mantenimiento de los equipos. El presente trabajo de suficiencia profesional tiene el propósito de mejorar las condiciones y calidad del aire al interior de un edificio de oficinas, para lograrlo, se evaluará las condiciones iniciales para rediseñar los sistemas de ventilación, que permitirán controlar los contaminantes del aire presentes al interior. La realización del trabajo, se inicia con la solicitud de información técnica, como planos de los sistemas de aire acondicionado de las oficinas, se verificarán las tasas de ventilación y las cargas térmicas de enfriamiento de los ambientes de oficina. Los resultados son comparados con el diseño existente y se determinaran los ambientes críticos. Para la evaluación de los ambientes críticos, se realizan mediciones de temperatura, humedad relativa, CO2, distribución, recirculación y velocidad de aire, estos resultados son evaluados y comparados con los valores mínimos permitidos para un edificio de oficinas, según normativas internacionales y nacionales, así como organismos de salud, como la organización mundial de la Salud (OMS) y el ministerio de Salud del Perú (MINSA). Los resultados obtenidos de las mediciones, junto con la evaluación de la información técnica, permitirán realizar los cálculos justificativos para determinar la selección de equipos y tecnologías a utilizar en el sistema de aire acondicionado existente. En el rediseño del sistema, se determinarán los nuevos parámetros de calidad de aire y confort térmico, que permitirán mejores condiciones, para el bienestar y salud de los ocupantes del edificio de oficinas. | es |
dc.description.abstract | Air pollution inside an office building is the cause of multiple health problems, which can range from fatigue or discomfort to symptoms compatible with allergies, infections and cancer. Air quality inside an office building is important because it is related to the well-being, comfort and productivity of the occupants. It depends on a number of factors, such as the quality of the outdoor air, the design of the ventilation system, the conditions of operation and maintenance of the equipment. The present work of professional sufficiency has the purpose of improving the conditions and quality of the air inside an office building, to achieve this, the initial conditions will be evaluated to redesign the ventilation systems, which will allow controlling the air pollutants present inside. The performance of the work begins with the request for technical information, such as plans for the air conditioning systems of the offices, the ventilation rates and the cooling thermal loads of the office environments will be verified. The results are compared with the existing design and the critical environments will be determined. For the evaluation of critical environments, measurements of temperature, relative humidity, CO2, distribution, recirculation and air speed are carried out, these results are evaluated and compared with the minimum values allowed for an office building, according to international and national regulations, as well as health organizations, such as the World Health Organization (WHO) and the Ministry of Health of Peru (MINSA). The results obtained from the measurements, together with the evaluation of the technical information, will make it possible to carry out the supporting calculations to determine the selection of equipment and technologies to be used in the existing air conditioning system. In the redesign of the system, the new parameters of air quality and thermal comfort will be determined, which will allow better conditions for the well-being and health of the occupants of the office building. | en |
dc.description.uri | Trabajo de suficiencia profesional | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Universidad Nacional de Ingeniería | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Calidad de aire interior | es |
dc.subject | Ventilación | es |
dc.subject | Contaminantes | es |
dc.title | Rediseño de un sistema de ventilación para controlar los contaminantes en el aire en un edificio de oficinas | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
thesis.degree.name | Ingeniero Mecánico Electricista | es |
thesis.degree.grantor | Universidad Nacional de Ingeniería. Facultad de Ingeniería Mecánica | es |
thesis.degree.level | Título Profesional | es |
thesis.degree.discipline | Ingeniería Mecánica-Eléctrica | es |
thesis.degree.program | Ingeniería | es |
renati.author.dni | 40710219 | - |
renati.advisor.dni | 06417352 | - |
renati.type | http://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional | es |
renati.level | http://purl.org/pe-repo/renati/nivel#tituloProfesional | es |
renati.discipline | 713076 | - |
renati.juror | Villavicencio Chávez, Manuel Augusto | - |
renati.juror | Ravelo Chumioque, José Jaime | - |
dc.publisher.country | PE | es |
dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#2.03.02 | es |
Aparece en las colecciones: | Ingeniería Mecánica y Electrica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
ayala_cs.pdf | 8,26 MB | Adobe PDF | Visualizar/Abrir | |
ayala_cs(acta).pdf | 85,66 kB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: