Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/22355
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorÑaupari Huatuco, Dionicio Zócimo-
dc.contributor.authorColcas Meneses, Miguel Horacio-
dc.creatorColcas Meneses, Miguel Horacio-
dc.date.accessioned2022-07-08T22:24:03Z-
dc.date.available2022-07-08T22:24:03Z-
dc.date.issued2021-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/22355-
dc.description.abstractSe han desarrollado las características técnicas de dos tecnologías de inversores fotovoltaicos, referente a su capacidad de inyectar potencia reactiva o no, para su posterior modelamiento en MATLAB e integración en una Red de Distribución de Baja Tensión (RDBT) modelada en DIgSILENT donde se plantearon posibles escenarios de los modos de operación de la generación fotovoltaica (𝐶𝑜𝑠𝜑 constante, regulación de tensión tipo Droop y sin regulación), comportamiento de carga y niveles de generación de potencia activa. Se monitorearon los indicadores distorsión armónica tales como la Distorsión armónica total (THD), corrientes armónicas en los diferentes puntos de la red de prueba entre otros parámetros pertinentes con el objetivo de analizar el efecto en el contenido armónico, su propagación en los diferentes puntos de la red y realizar una comparativa del efecto de los modos de operación de la generación fotovoltaica (GF), siendo la red evaluada, una red típica de distribución de baja tensión. Con base en los resultados de las simulaciones realizadas, se ha comprobado que, existirán escenarios donde la contaminación armónica se incrementara en mayor proporción, a causa de la integración de GF, con capacidad de inyectar potencia reactiva, en las redes de distribución. También se analizaron y establecieron los escenarios donde la contaminación armónica es crítica, así mismo, los factores que contribuyen a esta. De esta forma, también se evidencia, del análisis de los antecedentes nacionales, que, en la actualidad, en el Sistema Eléctrico Peruano y en el ámbito de contaminación armónica, no existe ningún control y/o supervisión de parte de los entes del estado, pudiéndose así degradar la calidad del producto eléctrico en las redes de distribución de baja tensión.es
dc.description.abstractThe technical characteristics of two photovoltaic inverter technologies have been developed, regarding their ability to inject reactive power or not, for subsequent modeling in MATLAB and integration in a Low Voltage Distribution Network (RDBT) modeled in DIgSILENT where possible scenarios of the GF operating modes (constant Cosφ, Droop type voltage regulation and no regulation), load behavior and active power generation levels. Harmonic distortion indicators such as Total Harmonic Distortion (THD), harmonic currents in the different points of the test network, among other pertinent parameters, were monitored in order to analyze the effect on the harmonic content, its propagation in the different points of the network and makes a comparison of the effect of the GF operating modes, the control network being a typical low voltage distribution network. Based on the results of the simulations carried out, it has been verified that there are scenarios where harmonic pollution increases in a greater proportion, a cause of the integration of GF, with the capacity to inject reactive power, into the distribution networks. The scenarios where harmonic pollution is critical were also analyzed and established, as well the factors that contributes to it. In this way, it is also evidenced, from the analysis of national antecedents, that, at present, in the Peruvian Electric System and in the field of harmonic pollution, there is no control and / or supervision on the part of state entities, thus being able to degrade the quality of the electrical product in the low voltage distribution networks.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectContaminación armónicaes
dc.subjectGeneración de energía fotovoltaicaes
dc.subjectSistema eléctrico peruanoes
dc.titleModelamiento de escenarios de contaminación armónica orientado a redes de distribución con presencia de generación fotovoltaicaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Electricistaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Eléctrica y Electrónicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Eléctricaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-8204-516Xes
renati.author.dni47435963-
renati.advisor.dni07091569-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline711046-
renati.jurorPalma García, Modesto Tomás-
renati.jurorSandoval Rodríguez, Alberto-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.02.01es
Aparece en las colecciones: Ingeniería Electrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
colcas_mm.pdf9,24 MBAdobe PDFVisualizar/Abrir
colcas_mm(acta).pdf1,74 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI