Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/22515
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSalazar Gavelán, Roger Edmundo-
dc.contributor.authorMorales Morales, Diego Manuel-
dc.creatorMorales Morales, Diego Manuel-
dc.date.accessioned2022-08-24T17:34:28Z-
dc.date.available2022-08-24T17:34:28Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/22515-
dc.description.abstractEl presente estudio se inicia con una exposición de las características del flujo de agua en las conexiones domiciliarias, porque en las conexiones domiciliarias se instalan Medidores de Agua. Se muestra que en las conexiones domiciliarias de agua se presentan descargas de diversas características en términos del volumen, caudal y tiempo que, a su vez, pasan por un medidor de agua, y a partir de allí se formula una propuesta de evaluación de los medidores en esas condiciones. Para tal fin se diseña un esquema para evaluar los medidores de agua con un enfoque desde el perfil del uso en las condiciones domiciliarias que están caracterizadas por descargas y estos por su duración y caudal del flujo. Luego, se analiza la relación entre el tiempo que demora un volumen de agua en pasar sin interrupción (duración) por un Medidor de Agua de Chorro Múltiple, con los Errores Relativos de Indicación generados en este instrumento. Los resultados del ensayo aplicado con diversas condiciones de caudal y duración muestran que el Error Relativo de Indicación aumenta cuando la duración de descarga disminuye. Las razones de este fenómeno se encuentran en la dinámica del rotor producto del pulso del flujo; se halla que es factible la desproporción entre, por una parte, el torque resultante durante la aceleración del rotor, y por otra, el torque luego de finalizado el pulso del flujo. Se recomienda realizar estadísticas para caracterizar los diversos tipos de descargas en los sistemas de instalaciones interiores de agua en distintas edificaciones. Porque dichas estadísticas, en comparación con la respuesta de determinados medidores a diversas descargas, puede constituir criterios para la selección de Medidores de Aguaes
dc.description.abstractThe present study begins with an exposition of the characteristics of the water flow in the household connections, because Water Meters are installed in the household connections. It is shown that in the household water connections there are discharges of various characteristics in terms of volume, flow and time that, in turn, pass through a water meter, and from there a proposal for evaluating the meters is formulated in those conditions. For this purpose, a scheme is designed to evaluate water meters with a focus from the profile of use in home conditions that are characterized by discharges and these by their duration and flow rate. Then, the relationship between the time it takes for a volume of water to pass without interruption (duration) through a Multiple Jet Water Meter is analyzed, with the Relative Errors of Indication generated in this instrument. Test results applied with various flow and duration conditions show that the Relative Error of Indication increases as the discharge duration decreases. The reasons for this phenomenon are found in the dynamics of the rotor, which is the product of the flow pulse; It is found that the disproportion between, on the one hand, the torque produced during the acceleration of the rotor, and on the other hand, the torque after the end of the flow pulse is feasible. It is recommended to carry out statistics to characterize the different types of discharges in the systems of indoor water installations in different buildings. Because these statistics, in comparison with the response of certain meters to various discharges, can constitute criteria for the selection of Water Meters.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectConexiones domiciliarias de aguaes
dc.subjectMedidores de aguaes
dc.subjectMedidor de agua de chorro múltiplees
dc.titleError de indicación por descargas intermitentes en el medidor de agua de chorro múltiplees
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.author.dni45231227-
renati.advisor.dni07577557-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorChávez Muñoz, Mario Aristides-
renati.jurorO'connor La Rosa, Roberto Javier-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
morales_md.pdf3,47 MBAdobe PDFVisualizar/Abrir
morales_md(acta).pdf85,22 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI