dc.identifier.urihttp://hdl.handle.net/20.500.14076/22564-
dc.description.abstractEl presente trabajo de suficiencia profesional tiene como objetivo diseñar y desarrollar el modelo hidráulico de los sistemas de agua potable y alcantarillado para la Asociación Pro Vivienda PROFAM Perú del distrito de Santa Rosa en el periodo de diseño del 2017 al 2037. El proyecto tiene como propósito la disminución de casos de enfermedades diarreicas y gastrointestinales de la población mejorando así su calidad de vida. La verificación hidráulica del sistema agua potable se realizó en base a un análisis en estado estático mediante el método de los polígonos de Thiessen para definir la asignación de caudal, y para el modelamiento hidráulico del sistema de alcantarillado se adoptó la condición de tirante normal en los colectores de salida de cuenca y se realizó en un tiempo de análisis estático. El resultado de este análisis hidráulico planteó para el sistema de agua potable una alternativa única que considera dos cisternas y tres reservorios; y respecto al sistema de alcantarillado se plantearon dos alternativas, donde una de ellas consiste en descargar las aguas residuales por gravedad a la PTAR PROFAM proyectada, y la otra considera un drenaje de las aguas residuales por medio de una serie de cámaras de bombeo y rebombeo para descargar en un colector proyectado en la carretera Panamericana Norte. Finalmente, para la evaluación económica de las alternativas, se utilizó la metodología costo beneficio para el sistema de agua potable y la metodología costo efectividad para el sistema de alcantarillado; concluyendo que el sistema de agua potable es social y financieramente viable, y para el sistema de alcantarillado que la segunda alternativa es la opción más técnica y económicamente viable.es
dc.description.abstractThe present work of professional sufficiency aims to design and develop the hydraulic model of drinking water and sewerage systems for the Pro Housing Association PROFAM Peru in the district of Santa Rosa in the design period from 2017 to 2037. The project aims to reduce cases of diarrheal and gastrointestinal diseases of the population to improve their quality of life. The hydraulic verification of the drinking water system was carried out based on a static analysis using the Thiessen polygon method; to define the flow allocation, and for the hydraulic modeling of the sewerage system, the normal flow condition was adopted in the basin outlet collectors and was carried out in a static analysis time. The result of this hydraulic analysis proposed a single alternative for the potable water system that considers two cisterns and three reservoirs; and with respect to the sewerage system, two alternatives were proposed, one of which consists of discharging wastewater by gravity to the projected PROFAM WWTP, and the other considers wastewater drainage through a series of pumping and overpumping chambers to discharge into a collector projected on the Panamericana Norte highway. Finally, for the social and economic evaluation of the alternatives, the cost-benefit methodology was used for the potable water system and the cost-effectiveness methodology for the sewerage system; concluding that the potable water system is socially and financially viable, and for the sewerage system that the second alternative is the most technically and economically viable option.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectDiseñoes
dc.subjectModelamientoes
dc.subjectAgua potablees
dc.subjectAlcantarilladoes
dc.subjectEvaluación económicaes
dc.titleModelamiento y diseño de sistemas de agua potable y alcantarillado para la A.P.V. PROFAM Perú distrito Santa Rosa - Lima, 2017-2037es
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.author.dni74020311-
renati.advisor.dni20055620-
renati.typehttp://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorChávez Muñoz, Mario Aristides-
renati.jurorO'connor La Rosa, Roberto Javier-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
eulogio_mj.pdf18,83 MBAdobe PDFVisualizar/Abrir
eulogio_mj(acta).pdf87,03 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI