Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/24542
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorGálvez Villacorta, Adolfo Guillermo-
dc.contributor.authorChe Alva, Edwin Luy-
dc.creatorChe Alva, Edwin Luy-
dc.date.accessioned2023-05-05T22:46:19Z-
dc.date.available2023-05-05T22:46:19Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/24542-
dc.description.abstractEl presente trabajo está orientado al estudio de las ventajas y desventajas del uso de disipadores sísmicos Shear Link Bozzo en una edificación esencial de concreto armado. Para este estudio se ha seleccionado una edificación esencial tipo centro de salud, la cual se diseñó de acuerdo al Reglamento Nacional de Edificaciones – Edición 2006. Luego, se realizó un nuevo diseño del edificio utilizando los disipadores sísmicos Shear Link Bozzo con el fin de estudiar cómo se modifica el comportamiento de la edificación. Para analizar el comportamiento de ambos tipos de edificaciones se realizaron análisis no lineales tiempo-historia utilizando el programa PERFORM 3D, para ello se seleccionaron 11 pares de registro sísmicos que fueron escalados a diferentes niveles de intensidades siguiendo los lineamientos de la norma FEMA P-58. La evaluación del desempeño de los edificios se utilizó la norma ASCE – 41-13. Se tomó como principales parámetros de comparación las distorsiones de entrepisos, aceleraciones de entrepisos y desempeño de los principales elementos estructurales como vigas, columnas y placas. Así mismo, con los resultados obtenidos de los análisis y mediante el programa PACT se cuantificó los daños en ambas estructuras en términos monetarios. Finalmente, con la metodología aplicada y los resultados obtenidos del estudio nos permitirá conocer la efectividad de los disipadores sísmicos Shear Link Bozzo en la reducción de daños en los elementos estructurales y el contenido de la edificación, así mismo, cuantificar en términos monetarios el desempeño sísmico para una mejor toma de decisión en proyectos futuros.es
dc.description.abstractThe present work is oriented to the study of the advantages and disadvantages of the use of Shear Link Bozzo seismic dissipators in an essential building of reinforced concrete. For this study, an essential health center type building has been selected, which was structurally designed according to the National Building Regulation - 2006 Edition. Then, a new design of the building was made using the Shear Link Bozzo seismic dissipators in order to study how the behavior of the building is modified. In order to analyze the behavior of both types of buildings, nonlinear time-history analyzes were performed using the PERFORM 3D program, for which 11 seismic record pairs were selected that were scaled to different levels of intensities following the guidelines of the FEMA P-58 standard. The evaluation of the performance of the buildings used the norm ASCE - 41-13. The main comparison parameters were the stories drifts, stories accelerations and performance of the main structural elements such as beams, columns and walls. Likewise, with the results obtained from the analysis and through the PACT program, the damages in both structures were quantified in monetary terms. Finally, with the methodology applied and the results obtained from the study, it will allow us to know the effectiveness of the Shear Link Bozzo seismic dissipators in reducing the damages of the structural elements and content of the building, as well as quantifying the seismic performance in monetary terms for a better decision making in future projects.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectConcreto armadoes
dc.subjectReglamento Nacional de Edificacioneses
dc.subjectDisipadores sísmicoses
dc.titleAnálisis comparativo de pérdidas entre una edificación esencial de concreto armado convencional y una con disipadores sísmicos SLBes
dc.typeinfo:eu-repo/semantics/masterThesises
thesis.degree.nameMaestro en Ciencias con Mención en Ingeniería Estructurales
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Civil. Unidad de Posgradoes
thesis.degree.levelMaestríaes
thesis.degree.disciplineMaestría en Ciencias con Mención en Ingeniería Estructurales
thesis.degree.programMaestríaes
renati.author.dni43109587-
renati.advisor.dni07817060-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#maestroes
renati.discipline732097-
renati.jurorTorres Matos, Miguel Ángel-
renati.jurorZavala Sánchez, Erick Cristian-
renati.jurorJiménez Yábar, Heddy Marcela-
renati.jurorGutiérrez Lázares, José Wilfredo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.01.04es
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
che_ae.pdf13,13 MBAdobe PDFVisualizar/Abrir
che_ae(acta).pdf197,01 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf293,57 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI