Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/2512
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMontoya Zavaleta, Modesto Edilberto-
dc.contributor.authorDefilippi Shinzato, Luis Atilio-
dc.creatorDefilippi Shinzato, Luis Atilio-
dc.date.accessioned2017-03-16T21:12:59Z-
dc.date.available2017-03-16T21:12:59Z-
dc.date.issued2016-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/2512-
dc.description.abstractDesde fines del siglo XX, el cáncer de mama se ha convertido en una de las enfermedades más frecuentes en las mujeres a partir de los 40 años de edad, situándose como la quinta causa de muerte por cáncer a nivel mundial, con una probabilidad de 1 a 8 de que se le diagnostique dicho cáncer y de 1 a 34 de morir por esta causa, según lo indica el Breast Cáncer Incidence and Mortality Worldwide of International Agency for Research of Cáncer 2010. La mamografía es el método utilizado para detectar el cáncer de mama, permitiendo su tratamiento y curación de la paciente. Este método utiliza radiación ionizante (rayos X) que tiene asociado un riesgo radiológico relacionado con la dosis depositada en el tejido de la mama. Sólo una imagen mamográfica de buena calidad permite el diagnóstico correcto, evitando diagnósticos incorrectos o repetición de exposiciones a los rayos X que repercuten en la salud de la paciente. El presente trabajo aplica el parámetro de la tasa de rechazo de imágenes en mamografía para determinar la calidad de las mismas en el servicio de mamografía del Instituto Nacional de enfermedades Neoplásicas (INEN) y utiliza este parámetro como indicador para la mejora del Sistema de Generación de Imágenes, reduciendo el número de imágenes repetidas y, por consiguiente, la dosis colectiva impartida a los pacientes. En el presente trabajo de tesis de investigación, se plantea y ejecuta una nueva categorización para las imágenes rechazadas, permitiendo ubicar la falla en el precitado Sistema de una forma más sencilla y rápida, mejorándose el servicio de mamografía del Instituto Nacional de enfermedades Neoplásicas (INEN) en sus ambientes, equipos, personal, etc., dando como logro total la reducción de la dosis colectiva en 16,2 % y la tasa de rechazo de imágenes en un 14 %, ubicándolas por debajo del nivel de tolerancia indicado por el Organismo Internacional de Energía Atómica (OIEA).es
dc.description.abstractSince the late twentieth century, breast cancer has become one of the most common diseases in women from 40 years of age, making it the fifth leading cause of cancer death worldwide, with a probability of 1 - 8 that the cancer is diagnosed and 1-34 to die for this cause, as indicated by the Breast Cancer Incidence and Mortality Worldwide of International Agency for Research on Cancer 2010. Mammography is the method used to detect breast cancer, allowing treatment and cure of the patient. This method uses ionizing radiation (X-rays) that has an associated radiological risk associated with the deposited in the breast tissue dose. Only one mammographic image quality allows the correct diagnosis and avoid misdiagnosis or repeated exposures to X-rays that affect the health of the patient. This paper applies the parameter of the rejection rate imaging in mammography to determine the quality of them in the mammography service of the National Institute of Neoplastic Diseases (NIND) and use this parameter as an indicator for the improvement of the Generation System Images, reducing the number of repeated images and therefore the collective dose imparted to the patient. In this thesis research, we propose and implements a new classification for rejected images, allowing locate the fault in the aforementioned system more quickly and easily, improving service Mammography INEN in their environment, equipment, personnel, etc., leading to overall achievement reducing the collective dose in 16.2% and the rate of rejection of images by 14%, placing them below the tolerance level indicated by the International Atomic Energy Agency (IAEA).en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectFísica médicaes
dc.subjectRadiobiologíaes
dc.subjectRadiación ionizantees
dc.subjectMamografíaes
dc.subjectProcesamiento de imágeneses
dc.titleReducción de la dosis colectiva impartida en exámenes de mamografía mediante el criterio de la imagen rechazadaes
dc.typeinfo:eu-repo/semantics/masterThesises
thesis.degree.nameMaestro en Ciencias con Mención en Física Médicaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ciencias. Unidad de Posgradoes
thesis.degree.levelMaestríaes
thesis.degree.disciplineMaestría en Ciencias con Mención en Física Médicaes
thesis.degree.programMaestríaes
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
defilippi_sl.pdf2,17 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI