Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/3553
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Gutiérrez Alfaro, Sergio | - |
dc.contributor.author | Acevedo, Asunción | - |
dc.contributor.author | Rodríguez, Juan | - |
dc.contributor.author | Carpio, Edward A | - |
dc.contributor.author | Manzano, Manuel A | - |
dc.creator | Gutiérrez Alfaro, Sergio | - |
dc.creator | Gutiérrez Alfaro, Sergio | - |
dc.date.accessioned | 2017-07-03T20:20:37Z | - |
dc.date.available | 2017-07-03T20:20:37Z | - |
dc.date.issued | 2015-08 | - |
dc.identifier.issn | 2682575 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.14076/3553 | - |
dc.description.abstract | BACKGROUND: The purpose of this work was to evaluate the disinfection capacity of two handmade low-cost devices based on solar photocatalytic disinfection (SPC-DIS): a plastic bottle (2 L) with a cylinder inside coated with TiO2 doped with zinc and a glass reactor (9 L) with an inner cylinder coated with pure TiO2. Disinfection experiments of wastewater-derived Escherichia coli, Enterococcus spp. and Clostridium perfringens (104–105 CFU per 100 mL) were carried out under natural sunlight during winter. RESULTS: Clostridium perfringens was the most resistant microorganism and E. coli the least in all cases. The SPC-DIS bottle achieved 100% disinfection for E. coli, but only 98.97% for Enterococcus spp. and 96.28% for C. perfringens. The SPC-DIS reactor achieved, under optimum operating conditions, 100% disinfection for E. coli, 100% for Enterococcus spp. and 99.44% for C. perfringens. Maximum sustainable flow rate (22 L min−1) and maximum illumination ratio (1:2) were the best operating conditions. Operating with recirculation (interrupted illumination) favored C. perfringens spore formation. Best kinetic models were biphasic for E. coli and log-linear for Enterococcus spp. and C. perfringens. CONCLUSION: The two new devices showed higher disinfection capacity than common PET bottles (increase in disinfection rates up to 1.5 and 4.6 times), proving to be promising alternatives to the traditional method SODIS. © 2015 Society of Chemical Industry | es |
dc.format | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | John Wiley and Sons Ltd | es |
dc.relation.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84941729237&doi=10.1002%2fjctb.4795&partnerID=40&md5=428da68c52e439df115aaeee1f48381a | es |
dc.rights | info:eu-repo/semantics/restrictedAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | es |
dc.source | Universidad Nacional de Ingeniería | es |
dc.source | Repositorio Institucional - UNI | es |
dc.subject | Solar disinfection | es |
dc.subject | Titanium dioxide | es |
dc.subject | Escherichia coli | es |
dc.subject | Enterococcus spp | es |
dc.subject | Clostridium perfringens | es |
dc.subject | Low cost | es |
dc.title | Solar Photocatalytic Water Disinfection of Escherichia coli, Enterococcus spp. and Clostridium Perfringens using different low-cost devices | es |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.journal | Journal of Chemical Technology and Biotechnology | es |
dc.identifier.doi | 10.1002/jctb.4795 | es |
dc.contributor.email | sergio.gutierrez@uca.es | es |
Aparece en las colecciones: | Instituto General de Investigación (IGI) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Solar Photocatalytic Water Disinfection of Escherichia coli, Enterococcus spp.pdf | 1,25 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: