Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/830
Título : Verificación experimental del estado límite de una estructura aporticada típica sometida a un sismo
Autor : Rivera Luna, María del Pilar
Asesor : Zavala Toledo, Carlos Alberto
Palabras clave : Análisis de vulnerabilidad;Estructuras aporticadas;Fallas en construcciones
Fecha de publicación : 1999
Editorial : Universidad Nacional de Ingeniería
Resumen : La presente investigación utiliza un método experimental y métodos analíticos para comparar el comportamiento de una estructura clásica, pórtico simple de una crujía, frente a una excitación sísmica. Para realizar el experimento se modela la estructura a escala 1:5 y utilizando la mesa vibradora se la sometió al sismo de Lima del 03 de Octubre 1974 por medio del programa "ONDMES" implementado en Lab-Windows. Este programa controla el movimiento de la mesa vibradora a través del manejo por computadora del envío de señales sísmicas y/o cualquier otro tipo de señal. En el modelo realizado se verificaron los patrones de comportamiento limite asociados a un proceso determinístico, demostrando por analisis teórico que el mecanismo de falla tipo panel es el que tiene mayor probabilidad de presentarse bajo la acción de la carga sísmica aplicada; habiéndose observado dicho mecanismo durante el experimento realizado. Para observar la aplicación de la Confiabilidad. Estructural como un método de diseño, se incluye un ejemplo teórico del calculo del β de confiabilidad asociado a los diferentes modos de falla de un pórtico simple.
This research makes use of experimental and analytical methods in order to compare the behavior of a classical structure, one-span frame, against a seismic excitation. To accomplish test the structure was modeled in a 1:5 scale and a shaking table test was carry out using the record of the Lima earthquake of October 03, 1974 by means of a program "ONDMES" implemented in the Lab-Windows programming language. This program controls the movement of the shaking table through a computer for to send seismic signals and/or others type signals. In the accomplished model the behavior standards limit associated with a deterministic process are verified, demonstrating theoretically that a panel type collapse mechanism has a greater probability to appear under on earthquake load; It was found that this mechanics of the collapse mode appeared during the experiment that was accomplished. In order to observing the Structural Reliability as a design method, an theoretical example to compute the β of reliability associating to the different kinds of collapse mechanism for an one-span frame was included.
URI : http://hdl.handle.net/20.500.14076/830
Derechos: info:eu-repo/semantics/restrictedAccess
Aparece en las colecciones: Maestría

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
rivera_lm.pdf4,31 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI