Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/9320
Título : Evaluación de la eficiencia de remoción de materia orgánica en humedales de flujo sub-superficial con Macrófita Chrysopogon Zizanioides a distintas alturas de lecho granular
Autor : Ruiz Raymundo, Armando Víctor
Asesor : Maldonado Yactayo, Víctor Antonio
Palabras clave : Lodos activados;Humedales artificiales;Chrysopogon Zizanioides
Fecha de publicación : 2017
Editorial : Universidad Nacional de Ingeniería
Resumen : En esta investigación se estudió la altura (lecho granular) de un humedal artificial subsuperficial con macrófita chrysopogon zizanioides y se obtendrá la mayor eficiencia en remoción de materia orgánica, para las condiciones climatológicas del Perú. Para alcanzar lo planteado se realizaron caracterizaciones diarias y semanales de los afluentes y efluentes de cada humedal de distinta altura de lecho granular (H1=0,6m; H2=0,8m y H3=1m). Variando el caudal de diseño (280 L/día) en el rango 280 L/dia-500 L/día. Se estudiaron 2 etapas. Etapa I: Con un caudal de 280 L/día 3 meses y 2 meses con un caudal de 430 L/día. Etapa II: Con un Caudal de 430 L/día 2 meses y 1 mes con un caudal de 500 L/día. Se demostró que las mejores eficiencias de remoción de materia orgánica en términos de DBO5 y DQO en la presente investigación se obtuvieron con el caudal de 430 L/día. Y mejor remoción en términos de Turbiedad y SST con el caudal de 500L/día. Las máximas eficiencias de remoción son: DQO 47,49% en H2=0,8m; DBO5 26,09% en H1=0,6m; SST 69,31% en H3=1,0m y Turbiedad 81,51% en H3=1,0m. Estos valores son los promedios finales en las dos etapas con todos los caudales evaluados (280 L/día, 430 L/día y 500 L/día) Comparando las eficiencias obtenidas con el Caudal de 430 L/día y el caudal de 500 L/día se demuestra que la eficiencia de los parámetros analizados decae en promedio 9%. El pH de los efluentes y afluente en el sistema experimental fueron constantes en toda la investigación, y no hubo ninguna variación significativa para el propósito de la presente investigación. La temperatura de los efluentes con respecto al afluente en términos generales presento una variación de 0,86C° en H1=0,6m; 0,71C°en H2=0,8m y 0.41C° en H3=1,0m. Cuyas desviaciones estándar son H1: 13,01%; H2:14,03% y H3:14,37%respectivamente (una muestra de 720 datos para cada una). La conductividad de los efluentes con respecto al afluente en el sistema experimental en toda la investigación en general presento un incremento de en promedio de 19,31 uS/cm de forma directa a la altura de lecho granular. Con una desviación estándar de 7.25%.
In this research the height (granular bed) of a subsurface artificial wetland with macrophyte chrysopogon zizanioides was studied and the highest efficiency in the removal of organic matter will be obtained for the climatological conditions of Peru. In order to achieve this, daily and weekly characterizations of the tributaries and effluents of each wetland of different granular bed height (H1=0.6m, H2=0.8m and H3=1m) were carried out. Varying the design flow rate (280 L/day) in the range 280 L/day-500 L/day. Two stages were studied. Stage I: With a flow rate of 280 L/day 3 months and 2 months with a flow rate of 430 L/day. Stage II: With a flow rate of 430 L/day 2 months and 1 month with a flow rate of 500 L/day. It was demonstrated that the best removal efficiencies of organic matter in terms of BOD5 and COD in the present investigation were obtained with the flow rate of 430 L/day. And better removal in terms of Turbidity and SST with the flow of 500 L/day. The maximum removal efficiencies are: COD 47.49% in H2=0.8m; BOD5 26.09% in H1=0.6m; SST 69.31% in H3=1.0m and Turbidity 81.51% in H3=1.0m. These values are the final averages in the two stages with all flows evaluated (280 L/day, 430 L/day and 500 L/day) Comparing the efficiencies obtained with the flow rate of 430 L/day and the flow rate of 500 L/day, it is shown that the efficiency of the parameters analyzed decreases by an average of 9%. The pH of the effluent and effluent in the experimental system were constant throughout the investigation, and there was no significant variation for the purpose of the present investigation. The temperature of the effluents with respect to the influent generally presents a variation of 0.86C ° in H1=0.6m; 0.71C ° in H2=0.8m and 0.41C ° in H3=1.0m. The standard deviations are H1: 13.01%; H2: 14.03% and H3: 14.37% respectively (a sample of 720 data for each). The conductivity of effluents with respect to the influent in the experimental system in all the research in general presented an increase of on average of 19.31 uS/cm of direct form to the height of granular bed. With a standard deviation of 7.25%.
URI : http://hdl.handle.net/20.500.14076/9320
Derechos: info:eu-repo/semantics/restrictedAccess
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
ruiz_ra.pdf3,18 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI