<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>DSpace Colección :</title>
  <link rel="alternate" href="http://hdl.handle.net/20.500.14076/60" />
  <subtitle />
  <id>http://hdl.handle.net/20.500.14076/60</id>
  <updated>2026-04-08T22:54:52Z</updated>
  <dc:date>2026-04-08T22:54:52Z</dc:date>
  <entry>
    <title>Integración de métodos avanzados de visión computacional para el desarrollo de un sistema de segmentación de lesiones en pie diabético</title>
    <link rel="alternate" href="http://hdl.handle.net/20.500.14076/29044" />
    <author>
      <name>Taipe Ramos, Lucas Nicolas</name>
    </author>
    <id>http://hdl.handle.net/20.500.14076/29044</id>
    <updated>2026-03-17T07:34:47Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Título : Integración de métodos avanzados de visión computacional para el desarrollo de un sistema de segmentación de lesiones en pie diabético
Autor : Taipe Ramos, Lucas Nicolas
Resumen : Este estudio presenta un sistema de visión por computadora que integra modelos clásicos y fundacionales basados en Transformers para segmentar lesiones de pie diabético, complicación frecuente y severa de la diabetes. Modelos fundacionales como Segment Anything Model, entrenados con millones de imágenes, permiten obtener segmentaciones precisas mediante prompts en lugar de costosos procesos de fine tuning. El flujo de trabajo consiste en lo siguiente. Primero YOLOv5 localiza la lesión; segundo EDSR aumenta la resolución de la región de interés; tercero SLIC genera superpíxeles y VGG16 extrae descriptores; cuarto una regresión logística clasifica cada superpíxel como lesión o piel sana; quinto los centroides positivos, las cajas de YOLOv5 y la imagen original actúan como prompt para SAM, que produce la máscara final aprovechando su atención global. En pruebas con un conjunto diverso de imágenes, el sistema alcanzó un Índice de Jaccard de 0.941 y un coeficiente de Dice de 0.969, superando el ajuste directo de SAM y enfoques puramente convolucionales, a la vez que redujo tiempo y coste computacional. La solución brinda una herramienta avanzada para monitorizar úlceras, disminuye el riesgo de infecciones y optimiza el seguimiento de la cicatrización en pacientes con pie diabético, al aplicar los avances más recientes en visión por computadora a esta área clínica.; This study introduces a computer-vision system that melds classical techniques with foundation models based on Transformers to segment diabetic-foot ulcers, a frequent and serious complication of diabetes. Foundation models such as the Segment Anything Model, trained on millions of images, can generate accurate segmentations via prompts instead of costly fine-tuning.&#xD;
The workflow proceeds as follows. YOLOv5 first locates the ulcer; EDSR then enhances the region’s resolution; SLIC forms superpixels and VGG16 extracts their descriptors; a logistic-regression classifier labels each superpixel as ulcer or healthy skin; finally, the positive centroids, YOLOv5 bounding boxes, and the original image serve as a prompt for SAM, which outputs the final mask using its global-attention mechanism.&#xD;
Tested on a diverse image set, the system achieved a Jaccard Index of 0.941 and a Dice coefficient of 0.969, outperforming direct SAM fine-tuning and purely convolutional approaches while cutting training time and computational cost.&#xD;
The resulting tool advances ulcer monitoring, lowers infection risk, and streamlines healing assessment in diabetic-foot patients by bringing the latest computer-vision breakthroughs to this clinical domain</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Diseño de implementación de una carga útil (payload) para estudiar el comportamiento de celdas solares de perovskita (PSC) en condiciones estratosféricas</title>
    <link rel="alternate" href="http://hdl.handle.net/20.500.14076/29043" />
    <author>
      <name>Gonzales Saenz, Gaus Abdul</name>
    </author>
    <id>http://hdl.handle.net/20.500.14076/29043</id>
    <updated>2026-03-17T07:34:42Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Título : Diseño de implementación de una carga útil (payload) para estudiar el comportamiento de celdas solares de perovskita (PSC) en condiciones estratosféricas
Autor : Gonzales Saenz, Gaus Abdul
Resumen : El presente trabajo desarrolló el diseño e implementación  de una carga útil (payload) la cual se expuso a condiciones estratosféricas a una altura de 36 km en New Mexico - Texas (34°46,73N; 108°9,83W). El lanzamiento se realizó en un globo estratosférico realizado por el programa de vuelo High Altitude Student Platform (HASP) que cuenta con el respaldo de NASA Balloon Program Office (BPO) y Louisiana Space Consortium (LaSPACE).&#xD;
Se realizó el diseño mecánico  y electrónico  del payload con la finalidad de  estudiar la influencia en la eficiencia de las celdas solares de perovskita (PSCs, del inglés perovskite solars cells) de 1 y 2 píxeles expuestas a condiciones estratosféricas por un periodo de 10,5  h.  Estas  PSCs  fueron  fabricadas  en  los  laboratorios  del  Instituto  Catalán  de Nanociencia y Nanotecnología (ICN2) de España.&#xD;
Para esto, durante el vuelo a la estratósfera se expusieron las PSCs y además se realizó la medición de parámetros  atmosféricos  (temperatura,  humedad, presión e  irradiancia); además de la medición de la eficiencia de las PSCs, antes y después del lanzamiento cuyas mediciones se realizaron en el laboratorio del ICN2.&#xD;
Este trabajo de investigación contribuye a la investigación de una nueva tecnología para energizar dispositivos espaciales que, además de tener un costo mucho menor comparado con la tecnología de Si y trijuntura de In, Ga y As, tienen métodos de fabricación menos sofisticados  que permitiría  que los mismos  dispositivos  espaciales puedan  fabricar  las PSCs.&#xD;
En la medición  de los parámetros  atmosféricos  se obtuvo  una irradiancia  máxima  &#xD;
de 1238,94 W/m2; además los datos registrados coinciden con los datos teóricos calculados cuando estos no son afectados por sombras u objetos aledaños al payload. La medición de  la  temperatura  de  las  PSCs  se  registraron  valores  entre  -32,12  °C  a  32,19  °C, registrándose  los valores más bajos en la tropopausa.  Asimismo,  en la estratósfera  se obtuvo una medición de la humedad relativa de 4,79 %.&#xD;
Con  respecto  a las PSC,  se obtuvo  que 10 celdas  se deterioraron  debido  a que  su encapsulamiento  fue dañado antes del lanzamiento mientras que las 5 celdas restantes tuvieron una retención del 67,56% su eficiencia, para la PSC de 1 píxel (ubicada en la cara frontal del payload), retenciones del 75,91 % y 81,53 % de la eficiencia para las PSCs de 2 píxeles (ubicadas  en la cara izquierda),  y retenciones  de 87,39 % y 79,53 % de  la eficiencia para las PSCs de 2 píxeles (ubicadas en la cara derecha del payload). Por lo que se  determinó  que  la  tecnología  de  las  PSCs  posee  condiciones  promisorias  como dispositivos energizantes a ser empleados en condiciones estratosféricas.; This  work  involved  designing  and  implementing  a  payload  exposed  to  stratospheric conditions at an altitude of 36 km in New Mexico - Texas (34°46,73N; 108°9,83W). The launch was performed on a stratospheric  balloon by the High Altitude Student Platform (HASP) flight program supported by NASA Balloon Program Office (BPO) and Louisiana Space Consortium (LaSPACE).&#xD;
The mechanical and electronic design of the payload was performed to study the influence on the efficiency of 1- and 2-píxel perovskite solar cells (PSCs) exposed to stratospheric conditions  for  10,5  h.    These  PSCs  were  manufactured  in  the  Catalan  Institute  of Nanoscience and Nanotechnology (ICN2) laboratories in Spain. To this end, the PSCs were exposed during the flight to the stratosphere, and atmospheric parameters (temperature, humidity, pressure and irradiance) were measured. The efficiency of the PSCs was also measured before and after the launch, measurements taken in the ICN2 laboratory.&#xD;
This research work contributes to the investigation of a new technology for powering space devices. In addition to being much cheaper than Si and In, Ga, and As trijunction technology, this technology also uses less sophisticated manufacturing methods that would allow the same space devices to manufacture PSCs Atmospheric   parameters   measurements   yielded   a   maximum   irradiance   of 1238,94W/m2. Furthermore, the recorded data coincides with the theoretical data calculated when they are not affected by shadows or objects surrounding the payload. Temperature measurement of the PSCs range from -32,12 °C to 32,19 °C, with the lowest values in the tropopause.  Likewise,  a relative  humidity  measurement  of 4,79%  was obtained  in the stratosphere.&#xD;
Regarding  the  PSCs,  it  was  obtained  that  10  cells  deteriorated  due  to  their encapsulation was damaged prior to launch while the remaining 5 cells retained 67,56% efficiency for the 1-píxel PSC (located on the front face of the payload), 75,91 %, 81,53 % efficiency retentions for the 2-píxel PSCs (located on the left face), and 87,39 % and 79,53%</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Localización de averías y buenas prácticas en el servicio de aire acondicionado automotriz</title>
    <link rel="alternate" href="http://hdl.handle.net/20.500.14076/29042" />
    <author>
      <name>Calderón Cahuana, Carlos Raúl</name>
    </author>
    <id>http://hdl.handle.net/20.500.14076/29042</id>
    <updated>2026-03-17T07:34:46Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Título : Localización de averías y buenas prácticas en el servicio de aire acondicionado automotriz
Autor : Calderón Cahuana, Carlos Raúl
Resumen : Este trabajo detalla el sistema de aire acondicionado automotriz, sus componentes, y recopila la experiencia de varios años de trabajo sobre la localización de averías frecuentes para los vehículos (sedan y camionetas). Se muestra un método a seguir para la localización de averías haciendo uso del manómetro múltiple para diagnosticar los problemas de enfriamiento en la cabina, donde las indicaciones típicas de presiones de los manómetros de baja y alta presión son fundamentales para el diagnóstico. Así mismo, se detalla el proceso completo de carga y descarga de refrigerante en los sistemas de aire acondicionado automotrices. Finalmente, se detallan buenas prácticas en los procedimientos frecuentes de servicio.; This work shows the automotive air conditioning system, its components, and gather the experience over years or work about regarding to troubleshooting common problems for vehicles (sedan and pickups). A method to follow is shown to find problems by using the manifold gauge to diagnose cooling problems in the cabin, where typical pressure indications from the low- and high-pressure gauges are essential for the diagnosis. Also, the use of the manifold gauge to diagnose cooling problems in the cabin, where typical pressure indications from the low- and high-pressure gauges are essential for the diagnosis. Likewise, the complete process of charging and discharging refrigerant in automotive air conditioning systems is detailed. Finally, good practices in frequent service procedures are detailed.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Fabricación y caracterización de electrodos nanoestructurados a base de composites de carbón activado/óxido de zinc para remoción de metales pesados en agua mediante desionización capacitiva</title>
    <link rel="alternate" href="http://hdl.handle.net/20.500.14076/29041" />
    <author>
      <name>Castillón Huerta, Ronald Jair</name>
    </author>
    <id>http://hdl.handle.net/20.500.14076/29041</id>
    <updated>2026-03-17T07:34:44Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Título : Fabricación y caracterización de electrodos nanoestructurados a base de composites de carbón activado/óxido de zinc para remoción de metales pesados en agua mediante desionización capacitiva
Autor : Castillón Huerta, Ronald Jair
Resumen : El presente trabajo estudia la desionización capacitiva (CDI) para remover metales pesados, específicamente cobre y cobalto. El principio consiste en aplicar una diferencia de poten- cial entre electrodos porosos, haciendo que los iones disueltos migren hacia el electrodo de carga opuesta (electrosorción), mientras el agua fluye perpendicular al campo eléctrico. Los electrodos, con sustrato de grafito y una película gruesa de un composite carbón acti- vado/ZnO como material electroactivo, fueron caracterizados mediante difracción de rayos X, microscopia electrónica de barrido, espectroscopia de dispersión de rayos X, método Brunauer-Emmett-Teller y voltamperometría cíclica. Esto permitió analizar la estructura del electrodo, estimar el ancho de los rods de ZnO (∼ 450 nm), el tamaño de poro (8 nm), la composición del composite y su capacitancia específica (37,86 ± 0,94 F/g). Se ensambló una celda CDI con diez electrodos y espaciadores, evaluando su desempeño con solu- ciones de CuCl2 y CoCl2 (10 mM) a distintos caudales (35∼105 mL/min) y los siguientes&#xD;
parámetros: capacidad de adsorción de sal (SAC), tasa de adsorción de sal (ASAR), masa&#xD;
&#xD;
de soluto removido (Neff), eficiencia de remoción de sal (nd) y consumo energético espe- cífico (SEC). Para CuCl2, a 95 mL/min se obtuvieron los mayores SAC (1,526 mg · g−1), ASAR (0,00678 mg · s−1 · g−1) y Neff (22,40 mg); mientras que a 35 mL/min, se alcanzaron los valores más altos de nd (6,89 %) y SEC (344,84 Wh/m3). CoCl2 mostró menores valo- res en todos los parámetros. Finalmente, se evaluó una mezcla de CuCl2 y CoCl2 a menor concentración (6 mM cada una) y adicionando la operación con caudales menores (15 y&#xD;
25 mL/min), alcanzando un rendimiento superior: SAC de 2,08 mg · g−1, Neff de 30,56 mg, ASAR de 0,00678 mg · s−1 · g−1, nd de 16,84 % y SEC de 347,57 Wh/m3. Estos resultados sugieren que reducir la concentración y la caudal mejora notablemente la eficiencia de la&#xD;
celda CDI.; This work studies capacitive deionization (CDI) for the removal of heavy metals, specifi- cally copper and cobalt. The principle is based on applying a potential difference between porous electrodes, causing dissolved ions to migrate toward the oppositely charged electro- de (electrosorption), while water flows perpendicularly to the electric field. The electrodes, composed of a graphite substrate and a thick film of a activated carbon/ZnO composite as the electroactive material, were characterized using X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy, Brunauer-Emmett-Teller method, and cyclic voltammetry. These techniques allowed the analysis of the electrode structure, esti- mation of ZnO rod width (∼450 nm), pore size (8 nm), composite composition, and specific capacitance (37.86 ± 0.94 F/g). A CDI cell was assembled with ten electrodes and spacers, and its performance was evaluated using 10 mM solutions of CuCl2 and CoCl2 at different&#xD;
flow rates (35∼105 mL/min) by measuring the following parameters: salt adsorption capacity&#xD;
&#xD;
(SAC), salt adsorption rate (ASAR), effective salt removal mass (Neff), salt removal efficiency (nd), and specific energy consumption (SEC). For CuCl2, the highest values of SAC (1.526 mg · g−1), ASAR (0.00678 mg · s−1 · g−1), and Neff (22.40 mg) were obtained at 95 mL/min, while the highest nd (6.89 %) and SEC (344.84 Wh/m3) were recorded at 35 mL/min. CoCl2 showed lower values across all parameters. Finally, a mixed solution of CuCl2 and CoCl2 at lower concentration (6 mM each) and additionally operating at lower flow rates (15 and&#xD;
25 mL/min), yielding superior performance: SAC of 2.08 mg · g−1, Neff of 30.56 mg, ASAR of 0.00678 mg · s−1 · g−1, nd of 16.84 %, and SEC of 347.57 Wh/m3. These results suggest that reducing feed concentration and flow rate significantly improves the CDI cell’s adsorption and removal efficiency.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
</feed>
