Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/20.500.14076/28816| Título : | Automatismo de cambio de ventilador de aire de una caldera de vapor acuotubular tipo D |
| Autor : | Sarrín Cépeda, César Fernando |
| Asesor : | Pissani Castro, Oscar Dante Victorio |
| Palabras clave : | Calderas de vapor;Automatización industrial;Ventiladores industriales |
| Fecha de publicación : | 2024 |
| Editorial : | Universidad Nacional de Ingeniería |
| Resumen : | En la refinería La Pampilla en el año 2016 se instaló una caldera de vapor acuotubular de tipo D la cual incluía dos ventiladores de aire de tiro forzado, uno para operar de forma continua mediante una turbina a vapor (VAT) y otro de reserva que operaba con un motor eléctrico (VAM). En el contexto de la reducción de emisiones de la compañía, se planteó utilizar el VAM en operación continua, mientras que el VAT quedaría como equipo de reserva.
El principal desafío asociado a este cambio es la posible interrupción del suministro eléctrico, lo que ocasionaría el paro de diferentes equipos eléctricos y unidades de proceso, por ello, para mitigar el escenario del paro súbito del VAM se ha propuesto modificar el automatismo existente, de tal forma que se ejecute de forma rápida y segura el cambio automático de VAM al VAT. En ese sentido, el objetivo del presente trabajo es asegurar la continuidad de operación del ventilador accionado por motor eléctrico.
Luego de la implementación de los cambios propuestos, se logró superar los problemas identificados, así como las pruebas en la puesta en servicio del nuevo automatismo.
Finalmente, la implementación del trabajo conlleva un aumento de eficiencia energética y reducción de emisiones que se producen por operar de forma continua un equipo eléctrico, en lugar de una turbina de vapor. At the La Pampilla refinery in 2016, a type D water-tube steam boiler was installed, which included two forced draft air fans, one to operate continuously through a steam turbine (VAT) and another as a reserve that operated with an electric motor (VAM). In the context of the company's emissions reduction, it was proposed to use the VAM in continuous operation, while the VAT would remain as reserve equipment. The main challenge associated with this change is the possible interruption of the electricity supply, which would cause the stoppage of different electrical equipment and process units, therefore, to mitigate the scenario of sudden stoppage of the VAM it has been proposed to modify the existing automation, so that the automatic change from VAM to VAT is executed quickly and safely. In this sense, the objective of this work is to ensure the continuity of operation of the fan driven by an electric motor. After the implementation of the proposed changes, the identified problems were overcome, as well as the tests in the commissioning of the new automation. Finally, the implementation of the work leads to an increase in energy efficiency and reduction of emissions that are produced by continuously operating an electrical equipment, instead of a steam turbine. |
| URI : | http://hdl.handle.net/20.500.14076/28816 |
| Derechos: | info:eu-repo/semantics/openAccess |
| Aparece en las colecciones: | Ingeniería Petroquímica |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| sarrin_cc.pdf | 4,99 MB | Adobe PDF | Visualizar/Abrir | |
| sarrin_cc(acta).pdf | 954,79 kB | Adobe PDF | Visualizar/Abrir | |
| informe_de_similitud.pdf | 1,35 MB | Adobe PDF | Visualizar/Abrir | |
| carta_de_autorización.pdf | 1,3 MB | Adobe PDF | Visualizar/Abrir |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons
Indexado por: