Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/28995
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorVillavicencio Chávez, Manuel Augusto-
dc.contributor.authorQuispe Alvarez, Daniel Dalí-
dc.creatorQuispe Alvarez, Daniel Dalí-
dc.date.accessioned2026-03-03T23:55:38Z-
dc.date.available2026-03-03T23:55:38Z-
dc.date.issued2025-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/28995-
dc.description.abstractEsta investigación tiene como objetivo mitigar la concentración de compuestos orgánicos volátiles (VOC) generados dentro de una planta de fabricación de pintura en el área de Molienda durante el proceso de mezcla en los tanques con agitadores. Durante el proceso de medición de la concentración de VOC se encontraron gases con concentraciones entre 500 y 1300 ppm, después de implementar el sistema de ventilación se lograron niveles de concentración entre 2 a 10 ppm reduciendo así el riesgo de la salud de los trabajadores por exposición a los VOC dentro de estos ambientes según exige la normativa nacional. Mitigar la concentración de los VOC se logró mediante el diseño de ventilación localizada, el cual depende de determinar el caudal de extracción y la potencia requerida. La verificación de la concentración de los VOC ha sido validada mediante mediciones con analizador de gases ubicándolo en la zona de respiración de los trabajadores por lo que, la metodología es de tipo aplicada. La investigación fue realizada tomando en cuenta antecedentes que describen el riesgo y problemas a la salud de los trabajadores en plantas de pintura debido a la exposición a solventes orgánicos volátiles. A su vez hay otras investigaciones que indican que estos sistemas constituyen un método son efectivos para tener un nivel adecuado de concentración de VOC. Se concluye que el sistema de ventilación localizada logra mitigar los VOC identificados y se recomienda dar seguimiento al funcionamiento del sistema de ventilación verificando el caudal de operación y midiendo periódicamente los niveles de VOC dentro de estos ambientes laborales en plantas de fabricación de pintura.es
dc.description.abstractThis research aims to mitigate the concentration of volatile organic compounds (VOC) generated within a paint manufacturing plant in the grinding area during the mixing process in agitator tanks. During the VOC concentration measurement process, gases with concentrations between 500 and 1,300 ppm were found. After implementing the ventilation system, concentration levels between 2 and 10 ppm were achieved, thus reducing the health risk to workers from exposure to VOC in these environments, as required by national regulations. Mitigation of VOC concentrations was achieved through the design of localized ventilation, which depends on determining the extraction flow rate and the required power. VOC concentration verification was validated through measurements with a gas analyzer located in the workers' breathing zone, thus using an applied methodology. The research was conducted based on historical data describing the risks and health problems faced by workers in paint plants due to exposure to volatile organic solvents. Other research indicates that these systems are effective in maintaining adequate levels of VOC concentrations. It is concluded that the localized ventilation system successfully mitigates the identified VOC, and it is recommended that ventilation system performance be monitored by verifying the operating flow rate and periodically measuring VOC levels in these work environments in paint manufacturing plants.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectSistemas de ventilaciónes
dc.subjectCompuestos orgánicos volátileses
dc.subjectVentilación localizadaes
dc.subjectLímites máximos permisibleses
dc.subjectPlanta de fabricación de pinturaes
dc.titleDiseño de un sistema de ventilación localizada para mitigar la concentración de compuestos orgánicos volátiles en el área de molienda de 50 m² para la fabricación de pinturaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Mecánico Electricistaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Mecánicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Mecánicaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0003-0142-7930es
renati.author.dni76326384-
renati.advisor.dni08197523-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline713076-
renati.jurorPáez Apolinario, Eliseo-
renati.jurorGalarza Soto, Walter Herbert-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.03.02es
Aparece en las colecciones: Ingeniería Mecánica y Electrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
quispe_ad.pdf3,22 MBAdobe PDFVisualizar/Abrir
quispe_ad(acta).pdf236,86 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf550,98 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf204,77 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI