dc.description.abstractEl presente trabajo de investigación busca dar solución al circuito de ventilación local con el cálculo de requerimiento de aire en cada uno de los proyectos mineros de exploración de la U.E.A Capitana ,asimismo se realiza un análisis integral del sistema de ventilación Caravelí haciendo uso principalmente del balance de aire en las estaciones de ingreso de aire fresco y estaciones de salida de aire viciado en superficie en U.E.A Capitana , asimismo se realiza el cálculo de requerimiento de aire global de la mina y se plantea la instalación de un ventilador secundario y/o principal como extractor de aire viciado en el Nv 2130 así como la implementación de una chimenea integral de ventilación como un troncal de salida de aire viciado .Además de ello se busca cumplir con la velocidad mínima de aire acorde a la legislatura minera. Esto se propone realizando el cálculo del requerimiento local en los proyectos mineros y presentados proyectos de infraestructura tales como chimeneas de ventilación conexiones de labores e instalando ventiladores. Se plantea la ejecución de un RB o RC y realizando el cálculo del diámetro optimo del RC o RB llegando a un diámetro de 2.8 m para una longitud de 132.5 m. Además de ello es importante conocer los tipos de gases que se generan en la U.E.A Capitana de Caravelí producto de la voladura y por la emisión de los equipos Diesel para conocer sus concentraciones límites permisibles. Asimismo, el costo de mejora de todo el circuito e de ventilación tanto integral como local se aproxima a un total de 1,580,523.00 US$ contemplando el ventilador secundario de 50KCFM en el Nv 2130.es
dc.description.abstractThis research work seeks to provide a solution to the local ventilation circuit with the calculation of air requirement in each of the mining exploration projects of the U.E.A Capitana, also a comprehensive analysis of the Caraveli ventilation system is performed using mainly the air balance in the fresh air intake stations and stale air exhaust stations on the surface in U. E. A Capitana. E.A Capitana, also the calculation of the global air requirement of the mine is made and the installation of a secondary and/or main fan as a stale air extractor in Nv 2130 is proposed, as well as the implementation of an integral ventilation chimney as a stale air exhaust trunk, in addition to this, the minimum air velocity according to the mining legislation is sought to be fulfilled. This is proposed by calculating the local requirement in the mining projects and presenting infrastructure projects such as ventilation chimneys, work connections and installing fans. It is proposed the execution of a RB or RC and making the calculation of the optimal diameter of the RC or RB arriving at a diameter of 2.8 m for a length of 132.5 m. In addition, it is important to know the types of gases generated in the U.E.A. Capitana de Caraveli as a result of blasting and the emission of diesel equipment to know their permissible limit concentrations. Likewise, the cost of improving the whole circuit and the emission of the diesel equipment will be determined in order to know their permissible limit concentrations.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectVentilaciónes
dc.subjectRaise Climberes
dc.subjectExtractores
dc.subjectCaudal de airees
dc.subjectChimeneaes
dc.titleAnálisis de circuito de ventilación integral y propuestas de mejora en el circuito de ventilación local en los proyectos de exploración minera en una zona Sur del países
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero de Minases
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Geológica, Minera y Metalúrgicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería de Minases
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0003-1078-4155es
renati.author.dni72753870-
renati.advisor.dni08079590-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline724026-
renati.jurorValverde Espinoza, Santiago Gualberto-
renati.jurorOyola Gonzáles, Hernán Gabriel-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.07.05es
Aparece en las colecciones: Ingeniería de Minas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
povis_rj.pdf2,81 MBAdobe PDFVisualizar/Abrir
povis_rj(acta).pdf51,7 kBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf91,07 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf88,35 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI