Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.14076/29265
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorTaipe Rojas, Javier Enrique-
dc.contributor.authorCastro Ortega, Milagros Elvira-
dc.creatorCastro Ortega, Milagros Elvira-
dc.date.accessioned2026-06-12T21:07:18Z-
dc.date.available2026-06-12T21:07:18Z-
dc.date.issued2025-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/29265-
dc.description.abstractEste trabajo de investigación presenta el análisis del riesgo de incendio en el Pabellón Central de la Universidad Nacional de Ingeniería, una edificación antigua inaugurada el 19 de julio de 1945. La edificación, destinada principalmente a oficinas del sector administrativo, cuenta con cinco pisos: sótano, primer, segundo, tercer y cuarto nivel, con una capacidad máxima de 1247 personas. El estudio tuvo como objetivo estimar el riesgo de incendio como parte de la seguridad integral de los trabajadores del Pabellón Central. Se empleó el método Gretener por su capacidad para ponderar integralmente factores de peligro, medidas de protección y exposición de personas. Los resultados mostraron un cociente de seguridad (γ) inferior a 1 en los 5 pisos, indicando que las medidas de protección actuales son insuficientes y que el edificio presenta un alto riesgo de incendio. Además, como parte del análisis de seguridad integral, se revisaron estudios anteriores realizados en el Pabellón Central, destacando las Pre- ITSE relacionadas con la seguridad, las instalaciones eléctricas y la estructura, llevadas a cabo en 2024. Sin embargo, las observaciones formuladas en dichas inspecciones aún no han sido levantadas. Asimismo, se consideró un estudio de vulnerabilidad sísmica y riesgo estructural que concluyó que frente a una demanda sísmica con un periodo de retorno de 225 años, el edificio sufriría daños materiales y riesgo para la vida humana. Los hallazgos demuestran que el Pabellón Central presenta simultáneamente alto riesgo de incendio y vulnerabilidad sísmica, exponiendo a sus trabajadores a condiciones de peligro que requieren atención inmediata.es
dc.description.abstractThis research paper presents an analysis of fire risk in the Central Pavilion of the National University of Engineering, an old building inaugurated on July 19, 1945. The structure, primarily used for administrative offices, consists of five floors: basement, first, second, third, and fourth levels, with a maximum capacity of 1,247 people. The study aimed to assess fire risk as part of the comprehensive safety measures for the Central Pavilion’s workers. The Gretener Method was used due to its ability to comprehensively evaluate hazard factors, protective measures, and human exposure. The results showed a safety coefficient (γ) below 1 on all five floors, indicating that current protective measures are insufficient and that the building presents a high fire risk. Additionally, as part of the comprehensive safety analysis, previous studies conducted on the Central Pavilion were reviewed, highlighting Pre-ITSE reports (Technical Safety and Engineering Inspections) related to safety, electrical systems, and structural integrity, carried out in 2024. However, the observations from these inspections have yet to be addressed. Furthermore, a seismic vulnerability and structural risk study was considered, concluding that in the event of an earthquake with a 225-year return period, the building would suffer material damage and pose a risk to human life. The findings demonstrate that the Central Pavilion simultaneously presents high fire risk and seismic vulnerability, exposing its workers to hazardous conditions that require immediate attention.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectUniversidad Nacional de Ingeniería (UNI)es
dc.subjectSalud ocupacionales
dc.subjectPrevención de incendioses
dc.subjectSeguridad industriales
dc.subjectRiesgo de incendioes
dc.subjectGestión de riesgoses
dc.subjectMétodo Greteneres
dc.titleEstimación del riesgo de incendio como parte de la seguridad integral de los trabajadores expuestos a las área del pabellón central de la Universidad Nacional de Ingenieríaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero de Higiene y Seguridad Industriales
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería de Higiene y Seguridad Industriales
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-9488-5836es
renati.author.dni75652460-
renati.advisor.dni10343176-
renati.typehttps://purl.org/pe-repo/renati/type#tesises
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales
renati.discipline022016-
renati.jurorRobles García, Eusebio-
renati.jurorHernández Carrillo, María Jesús-
dc.publisher.countryPEes
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.02es
Appears in Collections:Ingeniería de Higiene y Seguridad Industrial

Files in This Item:
File Description SizeFormat 
castro_om.pdf11,86 MBAdobe PDFView/Open
castro_om(acta).pdf777,06 kBAdobe PDFView/Open
informe_de_similitud.pdf372,03 kBAdobe PDFView/Open
carta_de_autorización.pdf1,14 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI