Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/21208
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRosado Aguirre, Estanislao Ubaldo-
dc.contributor.authorRodríguez Serna, Edgar Severo-
dc.creatorRodríguez Serna, Edgar Severo-
dc.date.accessioned2021-10-08T19:26:08Z-
dc.date.available2021-10-08T19:26:08Z-
dc.date.issued2021-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/21208-
dc.description.abstractEl Ministerio de Cultura viene construyendo actualmente el MUSEO NACIONAL DE ARQUEOLOGÍA DEL PERÚ (MUNA) , ubicado en el distrito de Lurín, provincia de Lima ; denominado “Mejoramiento Integral del Servicio de Interpretación del Patrimonio Cultural mediante la creación del Museo Nacional de Arqueología del Perú en el distrito de Lurín, Provincia de Lima, Departamento de Lima”. Las especificaciones técnicas y el diagrama unifilar del Tablero Principal de puesta en paralelo de los transformadores del sistema eléctrico indican que los Interruptores deben tener una capacidad de cortocircuito de 125 kA, y también que los interruptores de los Tableros Generales y de Distribución deberían ser seleccionados mediante un estudio de coordinación de protecciones elaborado por un software y deben cumplir selectividad total y/o parcial. Con el apoyo y asesoramiento de los Ingenieros de Bticino del Perú S.A. – Grupo Legrand representantes de la marca LEGRAND (FRANCIA) , fabricantes de equipos eléctricos ; analizamos las especificaciones técnicas , memoria descriptiva , diagramas unifilares y cuadro de cargas ; y utilizamos el software XL PRO3 TOOL SELECTIVITY & BACK-UP para seleccionar los Interruptores de los Tableros eléctricos que cumplan selectividad total y parcial ; y el software XL PRO3 CALCUL para realizar un estudio de selectividad completo del sistema eléctrico de baja tensión. Los resultados nos demuestran que la máxima intensidad de una falla de cortocircuito trifásico en las barras colectoras del Tablero Principal de puesta en paralelo de los transformadores es 98,126 kA ; por lo tanto pueden utilizarse Interruptores con poder de cortocircuito de 100 kA de la marca LEGRAND.es
dc.description.abstractThe Ministry of Culture is currently building the MUSEO NACIONAL DE ARQUEOLOGÍA DEL PERÚ (MUNA), located in the district of Lurín wich is the province of Lima named : “Mejoramiento integral del servicio de interpretación del patrimonio cultural mediante la creación del Museo Nacional de Arqueología del Perú en el distrito de Lurín , provincia de Lima , departamento de Lima” The technical specifications and the single-line diagram of the Main Board for commissioning Parallel electrical system transformers show that the switches must have a short circuit capacity value of 125 kA , and they also indicate that all switches of the ‘General’ and ‘Distribution’ Boards should be selected by means of a coordination of protections study prepared by a software and must comply with total and/or partial selectivity. With the support and advice of Ingenieros de Bticino del Perú S.A. - Legrand Group representatives of the LEGRAND brand (FRANCE), manufacturers of electrical equipment; we analyzed the technical specifications, descriptive memory, single line diagrams, and load chart ; We use the XL PRO3 TOOL SELECTIVITY & BACK-UP software to select the Electrical Panel Switches that met total and partial selectivity ; and the XL PRO3 CALCUL software for a complete selectivity study of the low voltage electrical system. The results show us that the maximum intensity of a three-phase short-circuit fault in the busbars of the Main Board of parallel transformers is 98,126 kA; therefore, switches with 100 kA short-circuit power of the LEGRAND brand can be used.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectSistema eléctricoes
dc.subjectSoftware XL PRO3 TOOL SELECTIVITY & BACK-UPes
dc.subjectAnálisis selectivoes
dc.titleEstudio de selectividad del sistema eléctrico de baja tensión del Museo Nacional de Arqueología del Perú mediante el uso del software XL PRO3 CALCUL DE LEGRANDes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Electricistaes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Eléctrica y Electrónicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Eléctricaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0003-3019-2456es
renati.author.dni08575742-
renati.advisor.dni08492101-
renati.typehttp://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline711046-
renati.jurorHuayllasco Montalva, Carlos Alberto-
renati.jurorRocha Jara, Alfredo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.02.01es
Aparece en las colecciones: Ingeniería Electrica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
rodriguez_se.pdf10,15 MBAdobe PDFVisualizar/Abrir
rodriguez_se(acta).pdf111,78 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI