Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.14076/21233
Title: Influencia de la inyección forzada de aire exterior para un sistema de climatización de una tienda comercial en Lima
Authors: Matazoglio Maccha, Juan Omar
Advisors: Ravelo Chumioque, José Jaime
Keywords: Climatización;Refrigeración;Tienda comercial
Issue Date: 2020
Publisher: Universidad Nacional de Ingeniería
Abstract: En la actualidad, las personas pasan más del 80% de su tiempo dentro de locales cerrados, ya sea en centros comerciales, centros empresariales, oficinas, entre otros y la población de Lima no es ajena a esta realidad. Esta situación conlleva a estar expuestos a enfermedades alérgicas y pulmonares que afectan la salud de las personas. Desde 1982, la OMS reconoce al Síndrome de Edificios Enfermos, como el conjunto de molestias y enfermedades originadas por la mala ventilación, descompensación de temperaturas, entre otros factores. De ahí la importancia de mejorar la calidad de aire interior y a su vez considerar el consumo de energía. El presente trabajo, en base a la problemática descrita tiene como propósito investigar y demostrar que la inyección forzada de aire exterior mejora la calidad de aire dentro de un local, además analizaremos su influencia en el consumo de energía. Para llegar a demostrar estos dos puntos, se realizó el diseño del sistema de climatización de una tienda comercial en Lima. Teniendo como punto de inicio la toma de datos del proyecto (ubicación, condiciones ambientales exteriores e interiores, descripción del local, entre otros), los cuales fueron empleados para los cálculos mediante el método CLTD/CLF. Luego se procedió a la obtención de resultados, generando una serie de cuadros los cuales ayudaron a concluir que la inyección forzada de aire exterior es indispensable en un sistema de climatización para una buena calidad de aire interior y finalmente con respecto al consumo de energía se puede determinar que es necesario primero hacer un estudio general para elegir el sistema de climatización que se adecue al tipo de funcionamiento del local, sus condiciones climáticas y geográficas, es así como se lograría obtener un ahorro de energía y no encarecer el proyecto.
Currently, people spend more than 80% of their time inside closed premises, whether in shopping malls, business centers, offices, among others, and the population of Lima is no stranger to this reality. This situation leads to being exposed to allergic and lung diseases that affect people's health. Since 1982, the WHO recognizes the Sick Building Syndrome, as the set of discomforts and diseases caused by poor ventilation, decompensation of temperatures, among other factors. Hence the importance of improving indoor air quality and in turn considering energy consumption. The purpose of this work, based on the problems described, is to investigate and demonstrate that the forced injection of outside air improves the quality of air inside a room, and we will also analyze its influence on energy consumption. In order to demonstrate these two points, the design of the air conditioning system of a commercial store in Lima was carried out. Taking as a starting point the data collection of the project (location, interior and exterior environmental conditions, description of the premises, among others), which were used for calculations using the CLTD / CLF method. Then, the results were obtained, generating a series of tables which helped to conclude that the forced injection of outside air is essential in an air conditioning system for good indoor air quality and, finally, regarding energy consumption, it is possible to Determine that it is necessary to first make a general study to choose the air conditioning system that suits the type of operation of the premises, its climatic and geographical conditions, thus achieving energy savings and not making the project more expensive.
URI: http://hdl.handle.net/20.500.14076/21233
Rights: info:eu-repo/semantics/restrictedAccess
Appears in Collections:Ingeniería Mecánica y Electrica

Files in This Item:
File Description SizeFormat 
matazoglio_mj.pdf27,86 MBAdobe PDFView/Open
matazoglio_mj(acta).pdf95,23 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI