Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.14076/22352
Title: Análisis del cumplimiento de la reserva rotante para regulación primaria de frecuencia en el sistema eléctrico interconectado nacional del Perú
Authors: Duran Farfán, Robinson Jesús
Advisors: Huayllasco Montalva, Carlos Alberto
Keywords: Sistema Eléctrico Interconectado Nacional;Regulación primaria de frecuencia
Issue Date: 2021
Publisher: Universidad Nacional de Ingeniería
Abstract: En el Sistema Interconectado Nacional se aplica el Procedimiento Técnico PR-21 para el cumplimiento de la Regulación Primaria de Frecuencia, teniendo en cuenta los requerimientos de la normativa vigente durante el año 2018. Se ha encontrado la problemática de corroborar la correcta aplicación de este Procedimiento Técnico en el Sistema Interconectado Nacional por su importancia para mantener la frecuencia del SEIN en los valores adecuados, en el presente informe se ha replicado y analizado el procedimiento técnico PR-21 para una muestra de Centrales representativas del SEIN. Para este propósito el presente informe está enfocado en los siguientes temas: 1) Planteamiento del problema de ingeniería: en ese apartado se describe el problema y se define el objetivo con sus respectivos alcances. 2) Marco Teórico Conceptual: en este apartado se describe la base teórica de la Regulación Primaria de Frecuencia para poder desarrollar la replicación del Procedimiento Técnico. 3) Metodología de solución del problema: en este punto se describe la metodología para resolver el problema de la aplicación de la Regulación Primaria de Frecuencia en el Sistema Interconectado Nacional incluyendo cálculos justificativos y evaluaciones de acuerdo a la normativa vigente. 4) Se describe el estado actual de la Regulación Primaria en el Sistema Interconectado Nacional. Habiéndose concluido que hay diferencias puntuales para algunos días, en la replicación del Procedimiento, es posible que COES no los considere debido a criterios internos. En el análisis realizado en el presente informe se ha verificado que el COES, en el marco de sus funciones, cumple las responsabilidades establecidas en el Procedimiento Técnico PR-21 para el cumplimiento de la Regulación Primaria de Frecuencia, se concluye que no existen diferencias significativas entre lo analizado por el COES y el presente informe.
In the Peruvian National Interconnected System, the Technical Procedure PR-21 applies for compliance of the Primary Frequency Regulation, according with the requirements of the regulation in force during 2018. The problem of corroborating the correct application of this Technical Procedure in the National Interconnected System has been detected for its importance in maintaining the frequency of the SEIN in the adequate values, in this report the technical procedure PR-21 has been replicated and analyzed for a sample of representative Central Power Plants of the SEIN. In order to this purpose, the present report is focused on the following topics: 1) Engineering Problem Statement: In this section, the problem is described and the objective is defined with its respective scopes. 2) Conceptual Theoretical Framework: in this section the basic theory of Primary Frequency Regulation is described in order to be able to develop the replication of the technical procedure. 3) Problem Solving Methodology: This section describes the methodology to solve the problem of the application of Primary Frequency Regulation in the Peruvian National Interconnected System including justifying calculations and evaluations according to the current regulations. 4) The status of Primary Frequency Regulation in the Peruvian National Interconnected System is described. It has been concluded that there are punctual differences for some days, in the replication of the Procedure, it is possible that COES does not consider them because of internal criteria. In the analysis made in this report, it has been verified that COES, within the role of its functions, complies with the responsibilities established in the Technical Procedure PR-21 for compliance with the Primary Frequency Regulation, it is concluded that there are no significant differences between the analysis made by COES and this report.
URI: http://hdl.handle.net/20.500.14076/22352
Rights: info:eu-repo/semantics/restrictedAccess
Appears in Collections:Ingeniería Electrica

Files in This Item:
File Description SizeFormat 
duran_fr.pdf6,5 MBAdobe PDFView/Open
duran_fr(acta).pdf4,07 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI