Title: | Prevención del gaseamiento en uso masivo del anfo en las operaciones mineras subterráneas de CÍA. Minera Raura S.A |
Authors: | Félix López, Rosas |
Advisors: | Castillo Alejos, Efraín Eugenio |
Keywords: | Operaciones mineras;Minería subterránea;Gaseamiento |
Issue Date: | 2021 |
Publisher: | Universidad Nacional de Ingeniería |
Abstract: | En el presente trabajo se demuestra que es posible utilizar el ANFO en las Operaciones Mineras Subterráneas de la Compañía Minera Raura S.A. para este propósito se ha evaluado tres variables independientes.
La primera variable fue verificar el Sistema de Ventilación con proyección a la profundización de la mina, comprobar en 105.40% la cobertura del ingreso de aire fresco y limpio y la demanda de aire en mina y finalmente verificar el balance en 3.90% del ingreso y salida de aire en mina.
La segunda variable del control de los gases remantes después del disparo fue controlada en las labores en un 100%. Para que ingresen a laborar los trabajadores de mina el supervisor con su equipo multigas monitorea los gases remanentes y deja registrado en el cuaderno de obra y tablero de monitoreo, adicionalmente todos los trabajadores tienen el monogas para detectar el gas CO que es el más peligroso. La tercera variable importante para evitar el accidente por gaseamiento es el comportamiento seguro del trabajador, este comportamiento hace seguimiento el supervisor colegiado por medio del POS “Programa de Observadores de Seguridad” y el VCT “Verificación del Ciclo de Trabajo”. Finalmente, el supervisor colegiado es evaluado mensualmente con más del 91% en su Gestión del IDSS “Índice de Desempeño de Seguridad del Supervisor”.
Finalmente, con esta propuesta se garantiza CERO registros por accidente de gaseamiento y un ahorro a la Empresa de US$ 409,395.38 anuales por uso masivo de ANFO en todas sus labores programadas. This work shows that it is possible to use the ANFO in Underground Mining Operations of Company Minera Raura S.A. For this purpose, three independent variables have been evaluated. The first variable was to verify the Ventilation System with projection to the deepening of the mine, to verify in 105.40% the coverage of the entrance of fresh and clean air and the demand for air in the mine and finally to verify the balance in 3.90% of the entrance and exit of air in mine. The second variable of the control of the remaining gases after the shot was controlled in the work in 100%. In order for the mine workers to enter to work, the supervisor with his multigas equipment monitors the remaining gases and records them in the work log and monitoring board, additionally all workers have the monogas to detect the CO gas, which is the most dangerous. The third important variable to avoid the gassing accident is the safe behavior of the worker, this behavior is monitored by the collegiate supervisor through the POS "Safety Observers Program" and the VCT "Verification of the Work Cycle". Finally, the collegiate supervisor is evaluated monthly with more than 91% in their IDSS Management "Supervisor Safety Performance Index". Finally, this proposal guarantees ZERO registrations for gassing accidents and a saving to the Company of US $ 409,395.38 per year due to massive use of ANFO in all its scheduled tasks. |
URI: | http://hdl.handle.net/20.500.14076/22488 |
Rights: | info:eu-repo/semantics/openAccess |
Appears in Collections: | Maestría |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
felix_lr.pdf | 5,02 MB | Adobe PDF | View/Open | |
felix_lr(acta).pdf | 93,29 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: