Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/22569
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorYaya Beas, Rosa Elena-
dc.contributor.authorSalinas Vargas, Christian Darío-
dc.creatorSalinas Vargas, Christian Darío-
dc.date.accessioned2022-08-31T16:44:10Z-
dc.date.available2022-08-31T16:44:10Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/22569-
dc.description.abstractLa investigación evalúa la implementación de un selector aerobio, ubicado en la cabecera del tanque de aireación principal, y su efecto en la reducción de la cantidad de filamentos del lodo y la calidad de sedimentación. Se instalaron 02 sistemas de lodos activados de mezcla completa a escala de laboratorio, en los cuales, un sistema contó con el selector instalado en la cabecera del reactor y el otro no; ambos sistemas contaron con una línea de recirculación y sedimentadores secundarios, fueron operados en paralelo y bajo las mismas condiciones de aireación y caudal (259.2 L/d). La investigación se desarrolló en 6 etapas, la primera etapa consistió en el arranque de los reactores, en esta etapa únicamente se operaron los reactores de lodos activados, durante la segunda etapa los sistemas operaron con los sedimentadores secundarios y también se recirculó el lodo, en la tercera etapa se instaló el selector en el sistema N°1; y durante la cuarta, quinta y sexta etapa se variaron las tasas de recirculación al 50%, 60% y 70% respectivamente. Los parámetros evaluados fueron la DBO5 (total y soluble), el IVL, la carga másica (F/M), los SST, SSV, el oxígeno disuelto, el pH, la turbiedad, la temperatura y la conductividad. Después de la instalación del selector se redujo el IVL del sistema N°1 en un 39.66% con respecto al sistema N°2 (el cual no conto con el selector), no obstante, no se consiguió obtener un valor inferior a 150 ml/g, salvo durante la etapa 6 (R=70%). Así mismo se observó que la cantidad de bacterias filamentosas también se redujo a una cantidad ocasional después de la instalación del selector, mientras que, sin esta unidad, la cantidad de filamentos fue abundante. También se observó que a una mayor tasa de recirculación se pudo reducir tanto los valores de IVL como la cantidad de microorganismos filamentosos en el lodo. Por otro lado, también se encontró que, después de la instalación del selector aerobio en la cabecera del reactor R1, en el sedimentador se observan microburbujas.es
dc.description.abstractThe research evaluates the implementation of an aerobic selector, located at the head of the main aeration tank, and its effect on reducing the number of sludge filaments and the quality of sedimentation. 02 complete mixing activated sludge systems were installed on a laboratory scale, in which one system had the selector installed at the head of the reactor and the other did not; Both systems had a recirculation line and secondary settlers, they were operated in parallel and under the same aeration and flow conditions (259.2 L/d). The investigation was developed in 6 stages, the first stage consisted of the start- up of the reactors, in this stage only the activated sludge reactors were operated, during the second stage the systems operated with the secondary settlers and the sludge was also recirculated, in in the third stage, the selector was installed in system No. 1; and during the fourth, fifth and sixth stages the recirculation rates were varied to 50%, 60% and 70% respectively. The parameters evaluated were BOD5 (total and soluble), SVI, mass load (F/M), SST, SSV, dissolved oxygen, pH, turbidity, temperature and conductivity. After the installation of the selector, the SVI of system N ° 1 was reduced by 39.66% with respect to system N ° 2 (which did not have the selector), however, it was not possible to obtain a value lower than 150 ml/g, except during stage 6 (R = 70%). Likewise, it was observed that the amount of filamentous bacteria was also reduced to an occasional quantity after the installation of the selector, while, without this unit, the amount of filaments was abundant. It was also observed that at a higher recirculation rate, SVI values and the amount of filamentous microorganisms in the sludge could be reduced. On the other hand, it was also found that, after the installation of the aerobic selector at the head of the R1 reactor, microbubbles are observed in the settler.en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectLodos activadoses
dc.subjectImplementación de selector aerobioes
dc.subjectCarga másica (F/M)es
dc.titleControl del Bulking filamentoso debido a una baja relación F/M de un sistema de lodos activados de mezcla completa por medio de un selector aerobioes
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Sanitarioes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Sanitariaes
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0002-6140-4266es
renati.author.dni75259160-
renati.advisor.dni10040514-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline733016-
renati.jurorSalazar Gavelán, Roger Edmundo-
renati.jurorAlarcón Cóndor, Juan Carlos-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.11.02es
Aparece en las colecciones: Ingeniería Sanitaria

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
salinas_vc.pdf6,01 MBAdobe PDFVisualizar/Abrir
salinas_vc(acta).pdf96,68 kBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI