Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.14076/23038
Title: | Evaluación del efecto pounding para el hospital regional Eleazar Guzmán Barrón de Chimbote |
Authors: | Gutierrez Leiva, José Luis |
Advisors: | Gálvez Villacorta, Adolfo Guillermo |
Keywords: | Comportamiento Sísmico;Efecto pounding;Software DIANA FEA;Software ETABS;Chimbote, Ancash (Perú : Distrito) |
Issue Date: | 2021 |
Publisher: | Universidad Nacional de Ingeniería |
Abstract: | En la actualidad, la norma sismorresistente peruana, nos da determinadas recomendaciones técnicas a seguir, con la finalidad de tener una estructura de buen comportamiento sísmico durante su vida útil.
Sin embargo, existen diferentes fenómenos estructurales productos del comportamiento dinámico de una estructura frente a un sismo, que no son consideradas en las normas, siendo uno de estos el efecto “pounding” entre estructuras adyacentes. Aun cuando la norma actual nos da determinadas recomendaciones que evitarían este efecto, la evaluación de este fenómeno no está incluida explícitamente como una recomendación. Esta situación se vuelve más compleja aun para estructuras sin diseño o con criterios sísmicos antiguos.
Basado en experiencias de grandes sismos pasados en el mundo y diferentes estudios realizados sobre este fenómeno, se puede afirmar que, de ocurrir el efecto pounding en ciertas estructuras, puede ocasionar un daño grave a las estructuras que interactúan, incluso llegar a tener colapso estructural. Por lo que realizar su estudio y determinar sus efectos es de suma importancia para tomar acciones preventivas en una estructura determinada.
En el presente trabajo se desarrolló una aplicación de la evaluación del efecto pounding a una edificación hospitalaria existente de categoría esencial, construida en la década de los 70 y ubicada en la ciudad de Chimbote – Perú.
Se empleó el software DIANA FEA y el software ETABS se elaboran los modelos estructurales, incluyendo la modelación de pounding, se realizaron los análisis sísmicos, obteniendo las respuestas estructurales sobre los efectos pounding, para luego ser revisados e interpretados. Currently, the Peruvian earthquake-resistant standard gives us certain technical recommendations to follow, in order to have a structure with good seismic behavior during its useful life. However, there are different structural phenomena, products of the dynamic behavior of a structure in the event of an earthquake, which are not considered in the standards, one of these being the “pounding” effect between adjacent structures. Even though the current standard gives us certain recommendations that would avoid this effect, the evaluation of this phenomenon is not explicitly included as a recommendation. This situation becomes even more complex for structures without design or with old seismic criteria. Based on experiences of large earthquakes in the past in the world and different studies carried out on this phenomenon, it can be affirmed that if the pounding effect occurs in certain structures, it can cause serious damage to the interacting structures, even have structural collapse. Therefore, conducting its study and determining its effects is of the utmost importance to take preventive actions in a given structure. In this paper, an application of the evaluation of the pounding effect will be developed to an existing essential category hospital building, built in the 70's and located in the city of Chimbote - Peru. Using the DIANA FEA software and the ETABS software, the structural models are elaborated, including the pounding modeling, the seismic analyzes will be carried out, obtaining the structural responses on the pounding effects, which will be reviewed and interpreted. |
URI: | http://hdl.handle.net/20.500.14076/23038 |
Rights: | info:eu-repo/semantics/restrictedAccess |
Appears in Collections: | Segunda Especialidad |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
gutierrez_lj.pdf | 9,49 MB | Adobe PDF | View/Open | |
informe_de_similitud.pdf | 145,79 kB | Adobe PDF | View/Open | |
gutierrez_lj(acta).pdf | 116,86 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: