Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.14076/23809
Title: | Evaluación del solvente S2 con respecto al solvente S1 en una planta piloto |
Authors: | Vicos Ventura, Jorge David |
Advisors: | Parra Villanueva, Hernán Ismael |
Keywords: | Extracción;Diluyente;Arrastre;Orgánico |
Issue Date: | 2022 |
Publisher: | Universidad Nacional de Ingeniería |
Abstract: | La presente tesis trata del estudio para reemplazar el diluyente S1 (Hidrocarburos C13-C16, isoalcanos) que, por decisión del fabricante, ya no se fabricaría, y por tanto no se abastecería a la planta de extracción por solventes. Para ello se preparó un programa de investigación que incluía pruebas en laboratorio y a escala de planta piloto para determinar las variaciones de las propiedades físicas y químicas de un nuevo diluyente: S2 (kerosene, C12H26−C15H32). Se evaluaron las propiedades físicas como: tiempo de separación de fases, tensión interfacial y viscosidad; y las propiedades químicas tales como eficiencia de extracción, re extracción, cinética de extracción y re extracción.
La realización de las pruebas en laboratorio ha permitido determinar que la evaporación de los diluyentes puros como el S2 (kerosene, C12H26−C15H32) es 2% mayor que el S1(Hidrocarburos C13-C16, isoalcanos), este resultado demostró el mayor consumo del nuevo reactivo por una mayor evaporación. Otro parámetro, es el incremento del arrastre del orgánico en el Raff y el arrastre de orgánico en el electrolito rico, asimismo, el tiempo de separación de fases de la etapa de extracción no hubo variación considerable, en la etapa de re extracción se obtuvo un incremento en los valores del tiempo de separación de fases, estos resultados están fuera del rango de trabajo.
Las evaluaciones demostraron que los métodos utilizados en este trabajo con respecto al reactivo de reemplazo no sería una buena alternativa del reactivo actual en uso. This thesis deals with the study to replace the diluent S1 (Hydrocarbons C13-C16, isoalkanes) that, by decision of the manufacturer, would no longer be manufactured, and therefore would not be supplied to the solvent extraction plant. For this, a research program was prepared that presented laboratory tests and a pilot plant scale to determine the variations of the physical and chemical properties of a new diluent: S2 (kerosene, C12H26−C15H32). Physical properties such as: phase separation time, interfacial tension and viscosity were evaluated; and chemical properties such as extraction efficiency, re- extraction, extraction and re-extraction kinetics. Carrying out tests in the laboratory has made it possible to determine that the evaporation of pure diluents such as S2 (kerosene, C12H26−C15H32) is 2% greater than S1 (Hydrocarbons C13-C16, isoalkanes), this result revealed the highest consumption of new reagent by further evaporation. Another parameter is the increase in the drag of the organic in the Raff and the drag of organic in the rich electrolyte, similar, the time of phase separation of the extraction stage there was no considerable variation, in the re-extraction stage a increase in the values of the phase separation time, these results are outside the working range. The evaluations showed that the methods used in this work regarding the replacement reagent would not be a good alternative to the current reagent in use. |
URI: | http://hdl.handle.net/20.500.14076/23809 |
Rights: | info:eu-repo/semantics/openAccess |
Appears in Collections: | Ingeniería Metalúrgica |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
vicos_vj.pdf | 1,98 MB | Adobe PDF | View/Open | |
informe_de_similitud.pdf | 93,76 kB | Adobe PDF | View/Open | |
vicos_vj(acta).pdf | 72,51 kB | Adobe PDF | View/Open | |
carta_de_autorización.pdf | 133,42 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: