Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.14076/25262
Title: | Formulación de gestión de riesgos para un sistema de tratamiento para el mejoramiento de aceites lubricantes dieléctricos con un elevado grado de toxicidad |
Authors: | Renteria Robles, Diego Jesus |
Advisors: | Pérez Estrella, Mauro |
Keywords: | Aceites lubricantes;Sistema de tratamiento;Dieléctricos |
Issue Date: | 2023 |
Publisher: | Universidad Nacional de Ingeniería |
Abstract: | El presente trabajo de investigación, es desarrollado como un tema de gestión de riesgos, tiene como objetivo, reducir las concentraciones de los niveles de los policlorobifenilos a valores inferiores de 50 ppm, que deben estar presentes en los aceites dieléctricos; Los Policlorobifenilos (PCB), para uso de tipo industrial, de acuerdo con antecedentes de trabajos de investigación, se determinó que son altamente cancerígenos como una amenaza latente para la salud y el medio ambiente. Hay que tener en cuenta que existen LMP (límites máximos permisibles) de los PCB en los aceites usados, dentro de este trabajo se va a proponer el tratamiento químico para mejorar y reducir el riesgo sobre este compuesto químico. Para este tema de investigación, las muestras analizadas superan los 50 ppm, los aceites dieléctricos procedentes de los transformadores y condensadores eléctricos contaminados, fueron tratados, mediante el tratamiento de los PCB, con el método de declorinación química. Como un medio o tratamiento eficiente. Los medios ejecutados para este tipo de investigación fueron en la relación del sistema de gestión de riesgos y ambiental para los PCB, bajo los parámetros de los LMP, con algunos detectores de PCB, obteniendo un descarte para realizar el tratamiento de los que superaron los LMP. Siendo una investigación no experimental, describiendo la gestión ambiental y de riesgo de los fluidos dieléctricos (aceites) usados. Se mencionan muestras que son tomadas en la zona de recolección de las purgas de los transformadores. Para lograr el objetivo principal, se ha hecho una serie de revisiones de la bibliografía existente en este tema, así como de diversas, tecnologías y alternativas de tratamiento químico para restringir y moderar el riesgo sobre la formación de los policlorobifenilos, y se ha determinado el mejor método del tratamiento de declorinación química. Para el presente trabajo de investigación debemos investigar cuál es el potencial riesgo contra la salud y el medio ambiente. Palabras claves: Fluidos Dieléctricos, Sistema de Gestión de riesgos, Tratamiento del PCB. The present research work was motivated by a risk management issue, the main objective is to reduce the concentrations of the levels of polychlorinated biphenyls to values lower than 50 ppm, which may be present in dielectric oils; Polychlorinated biphenyls (hereinafter PCB), according to the latest research work, it was determined that they are carcinogenic as a threat to health and the environment. Knowing and identifying the LMP (maximum permissible limits) of the PCBs in the used oils, it is possible to propose the treatment of the chemical to improve the good performance, To know and evaluate in each point (location) of the samples those that exceed 50 ppm. Dielectric oils from contaminated electrical transformers and capacitors; were treated, through the destruction of PCBs, with the method of chemical dechlorination. The instruments executed for this type of investigation were in the relationship of the risk and environmental management system for PCBs, giving an assessment of the LMP, with the Clor-N-Oil 50 PCB detector kits, obtaining a discard to perform the treatment of those that exceeded the LMP. Being a non-experimental investigation, describing the environmental management of used dielectric fluids (oils). Samples that are taken in the transformer purge collection area are mentioned. Random samples were obtained with positive results, and it is considered variables such as; Temperature, volume, concentration, time and reaction rate; concentrations to 1 ppm. To achieve the main objective, a series of reviews of the existing bibliography on this topic as well as various technologies and alternatives of chemical treatment to restrict the formation of polychlorinated biphenyls has been evaluated and made, and it has been determined that the method of chemical dechlorination treatment, for this research work we are for this case we must investigate what is the potential risk against humans and the environment. |
URI: | http://hdl.handle.net/20.500.14076/25262 |
Rights: | info:eu-repo/semantics/restrictedAccess |
Appears in Collections: | Ingeniería Química |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
renteria_fd.pdf | 2,2 MB | Adobe PDF | View/Open | |
informe_de_similitud.pdf | 76,43 kB | Adobe PDF | View/Open | |
renteria_fd(acta).pdf | 87,63 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: