Please use this identifier to cite or link to this item:
http://hdl.handle.net/20.500.14076/26642
Title: | Influencia de la variación del porcentaje de agregado fino y grueso en concretos de alta resistencia |
Authors: | Ávila Cotrina, William Ernesto |
Advisors: | Cachay Huamán, Rafael |
Keywords: | Concreto de alta resistencia;Resistencia a la compresión;Resistencia del concreto;Material aglomerante |
Issue Date: | 2023 |
Publisher: | Universidad Nacional de Ingeniería |
Abstract: | En el presente informe de investigación fue realizado con el objeto de observar la influencia que se da en el concreto de alta resistencia cuando se varia la cantidad de agregados (arena gruesa y piedra chancada).
Con el fin de observar los cambios en la resistencia que sufre el concreto, bajo estas modificaciones, es que se elabora este informe de investigación, utilizando agregados de la cantera de Carapongo, con cemento tipo I y utilizando aditivo superplastificante reductor de agua. para ello se desarrolló el diseño de mezcla patrón con el método de máxima compacidad para cada una de las relaciones de a/c de 0.25,0.30 y 0.35.
Ya en su estado rígido se ensayó las muestras en los periodos de 7, 14 y 28 días, realizando la comparación de cada una de estas variaciones, con su diseño patrón, para cada relación de a/c. Ensayos como la compresión axial y tracción por compresión diametral, los que mayormente se usa dentro del rubro de la construcción.
Los resultados obtenidos se evaluaron a través del método del análisis de varianza, cuyo planteamiento de hipótesis estadística se planteó para su hipótesis nula, "la variación de agregado fino y grueso no modifica al concreto elaborado con el diseño patrón” y para su hipótesis alterna "la variación de porcentaje de agregado fino y grueso si modifica al concreto elaborado con el diseño patrón”.
Finalmente se mostrará el análisis realizado en base a los resultados, sacando conclusiones puntuales de lo investigado y dando recomendaciones a seguir. This research report was carried out with the purpose of observing the influence that occurs in high strength concrete when the amount of aggregates (coarse sand and crushed stone) is varied. With the purpose of observing the changes in the resistance that the concrete suffers under these modifications, this research report is elaborated, using aggregates from the Carapongo quarry, with type I cement and using superplasticizing water-reducing admixture. For this purpose, the design of the standard mix was developed with the maximum compactness method for each of the w/c ratios of 0.25, 0.30 and 0.35. Once in its rigid state, the samples were tested for periods of 7, 14 and 28 days, comparing each of these variations with its standard design for each w/c ratio. Tests such as axial compression and traction by diametral compression, which are mostly used in the construction industry. The results obtained were evaluated through the analysis of variance method, whose statistical hypothesis was stated for its null hypothesis, "the variation of fine and coarse aggregate does not modify the concrete produced with the standard design" and for its alternate hypothesis "the variation of the percentage of fine and coarse aggregate does modify the concrete produced with the standard design". Finally, the analysis carried out based on the results will be shown, drawing specific conclusions from the research and giving recommendations to follow. |
URI: | http://hdl.handle.net/20.500.14076/26642 |
Rights: | info:eu-repo/semantics/openAccess |
Appears in Collections: | Ingeniería Civil |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
avila_cw.pdf | 6,71 MB | Adobe PDF | View/Open | |
avila_cw(acta).pdf | 517,92 kB | Adobe PDF | View/Open | |
carta_de_autorización.pdf | 430,19 kB | Adobe PDF | View/Open | |
informe_de_similitud.pdf | 579,79 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License
Indexado por: