dc.identifier.urihttp://hdl.handle.net/20.500.14076/26889-
dc.description.abstractEn la presente investigación, se evaluó la concentración de PM2.5 durante el periodo (27 de octubre al 23 de noviembre del año 2021 en el campus de la UNI, para ello se recolectaron muestras de PM2.5 a través de un equipo de muestreo de partículas a bajo volumen marca TCR Tecora modelo Bravo Plus en 4 puntos ubicados dentro del campus. Las 20 muestras de PM2.5 no exceden el Estándar Nacional de Calidad Ambiental del Aire (ECA). Sin embargo, 9 muestras de PM2.5 exceden el Valor Guía Actualizada de la Organización Mundial de la Salud (OMS). Se encontró también que las concentraciones de este contaminante están en el rango de 15.42 a 25.83 pg/m3, lo cual arroja valores de Índice de Calidad del Aire (ICA) que van de 41.83 a 79.87 y cuya calificación correspondiente es de calidad de aire moderada. Se observó también en las pruebas estadísticas, que las concentraciones de PM2.5 son similares durante los 5 días de la semana y son similares en los puntos de monitoreo (UNI-01 y UNI-04), lo cual indica que a nivel del campus la distribución de la concentración de PM2.5 es relativamente homogénea. De igual forma se observó en las pruebas estadísticas que la concentración de PM2.5 tiene tendencia inversa con la humedad relativa y velocidad del viento, y una tendencia directa con la temperatura y radiación solar. También se ha realizado una comparación al comportamiento que tuvo el PM2.5 durante el periodo de pandemia por COVID-19 (años 2020 y 2021) con respecto al año 2019, para lo cual se ha tomado como referencia el estudio del SENAMHI que se elaboró durante el año 2020. Por último, se determinó la distribución espacial, en donde se aprecia que la mayor concentración de PM2.5 se da en áreas colindantes al punto de monitoreo UNI-02 y una menor concentración de PM2.5 en áreas colindantes al punto de monitoreo UNI-03.es
dc.description.abstractIn the present investigation, the concentration of PM2.5 was evaluated during the period (October 27 to November 23, 2021 on the UNI campus, for which PM2.5 samples were collected through sampling equipment of low volume particles TCR Tecora brand Bravo Plus model at 4 points located within the campus. The 20 samples of PM2.5 do not exceed the National Environmental Air Quality (ECA) Standard.However, 9 PM2.5 samples exceed the Updated Guide Value of the World Health Organization (WHO).It was also found that the concentrations of PM2.5 this pollutant are in the range of 15.42 to 25.83 pg/m3, which yields Air Quality Index (ICA) values ranging from 41.83 to 79.87 and whose corresponding rating is moderate air quality. It was also observed in the test’s statistics, that the concentrations of PM2.5 are similar during the 5 days of the week and are similar at the monitoring points (UNI-01 and UNI-04), which indicates that at the campus level the distribution of the concentration of PM2.5 is relatively homogeneous. In the same way, it was observed in the statistical tests that the concentration of PM2.5 has an inverse trend with relative humidity and wind speed, and a direct trend with temperature and solar radiation. A comparison has also been made of the behavior of PM2.5 during the COVID-19 pandemic period (years 2020 and 2021) with respect to the year 2019, for which the SENAMHI study that was prepared has been taken as a reference during the year 2020. Finally, the spatial distribution was determined, where it can be seen that the highest concentration of PM2.5 occurs in areas adjacent to the UNI- 02 monitoring point and a lower concentration of PM2.5 in areas adjacent to the monitoring point UNI-03en
dc.description.uriTesises
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectPM2.5es
dc.subjectDistribución espaciales
dc.subjectPandemiaes
dc.subjectEmergencia sanitariaes
dc.titleDeterminación del nivel de contaminación atmosférica por PM 2.5 en el campus de la Universidad Nacional de Ingeniería, durante el periodo de pandemia por COVID-19es
dc.typeinfo:eu-repo/semantics/bachelorThesises
thesis.degree.nameIngeniero Ambientales
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Ambientales
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Ambientales
thesis.degree.programIngenieríaes
renati.advisor.orcidhttps://orcid.org/0000-0003-0799-6640es
renati.author.dni70106421-
renati.advisor.dni08120124-
renati.typehttp://purl.org/pe-repo/renati/type#tesises
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales
renati.discipline521066-
renati.jurorDíez Chirinos, César Manuel Sebastián-
renati.jurorValdivia Maldonado, Pedro Oswaldo-
dc.publisher.countryPEes
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.07.01es
Aparece en las colecciones: Ingeniería Ambiental

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
quispe_bl.pdf10,38 MBAdobe PDFVisualizar/Abrir
informe_de_similitud.pdf540,46 kBAdobe PDFVisualizar/Abrir
quispe_bl(acta).pdf219,51 kBAdobe PDFVisualizar/Abrir
carta_de_autorización.pdf1,45 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI