Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/20.500.14076/9684
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMendoza Apolaya, Atilio-
dc.contributor.authorMartínez Aguirre, Elva María-
dc.creatorMartínez Aguirre, Elva María-
dc.date.accessioned2018-03-26T17:55:14Z-
dc.date.available2018-03-26T17:55:14Z-
dc.date.issued2014-
dc.identifier.urihttp://hdl.handle.net/20.500.14076/9684-
dc.description.abstractEl presente estudio corresponde a la caracterización medioambiental del subsuelo de una instalación industrial además de considerar la eventual propuesta de actuaciones correctivas (remediación) en caso de obtener alguna afección. La instalación, objeto de estudio, está ubicada en una zona industrial de la provincia constitucional del Callao y se encuentra operando desde hace 20 años. Geológicamente, se sitúa sobre materiales cuaternarios recientes que forman parte del último tramo del cono deyectivo del río Rímac. El nivel de agua subterránea se encuentra a 3,5 metros de profundidad. Para determinar la caracterización se realizaron trabajos de campo, gabinete y laboratorio, estructurados en dos fases: En la Fase I se realizaron trabajos de gabinete como investigación bibliográfica y en la Fase II se realizaron labores de campo que consistió básicamente en la interpretación hidrogeológica con la ejecución de 6 sondeos de 8 metros de profundidad con la instalación de piezómetros en cada uno de ellos y la toma de muestras de suelo y agua para su respectivo análisis. A las muestras de suelo y agua se le realizaron analíticas como cantidad de metales, TPH (Hidrocarburos Totales de Petróleo), PAH’s (Compuestos Aromáticos Policíclicos), pesticidas orgánicos clorados entre otros. Para la valoración de los resultados analíticos obtenidos en suelo, se tomaron como referencia legislaciones europeas, (Legislación española, estándares de calidad del Real Decreto 9/2005 del 14 de enero y Legislación Canadiense, Canadian Environmental Quality Guidelines-CEQG), debido a que en la fecha de la realización del estudio aún no se contaba con ninguna legislación ambiental peruana para suelos. Para valorar los resultados analíticos obtenidos en aguas subterráneas, se utilizaron los Estándares Nacionales de Calidad Ambiental para Agua, Decreto Supremo Nº 002-2008-MINAM. Como era de esperar, según los antecedentes analizados, los resultados analíticos mostraron concentraciones de TPH, PAH, pesticidas orgánicos clorados e hidrocarburos clorados volátiles, como tetracloroetileno y cloruro de vinilo, este último específicamente en agua.es
dc.description.abstractThe purpose of the present study was to characterize the subsurface environment at an industrial facility. In addition to considering the characterization, the present study also take into account corrective actions (remediations) in case to get any environmental risks. The industrial facility is located in an industrial area of the Constitutional Province of Callao and it has been operating for 20 years. Geologically, it is situated on recent quaternary materials that are part of the final installment of the Rimac river alluvial cone. The groundwater level is 3.5 meters deep. Field, office and laboratory works were conducted in order to determine the characterization. The characterization was carried out in two phases. In the first phase, office work as library research was performed. In the second phase, field work that was basically the hydrogeological interpretation was performed. The hydrogeological interpretation was carried out using 6 drilling. Each drilling reach 8 meters deep. In each drilling piezometers were installed. In addition, soil and water samples were collected for the respective analysis. A soil sample and water was performed analysis of certain parameters such as amount of metals, TPH (Totals Petroleum Hydrocarbons), PAH's (Polycyclic Aromatic Compounds), chlorinated organic pesticides among others. To evaluate the analytical results of soil were taken as reference European legislation (Spanish legislation, quality standards of Royal Decree 9/2005 of 14 January and Canadian Legislation, Canadian Environmental Quality Guidelines-CEQG) due to on the date of the study is not yet had any Peruvian environmental legislation related to soils. To assess the analytical results of groundwater, the National Environmental Quality Standards for Water, Supreme Decree No. 002-2008-MINAM were used. As expected, based on the information analyzed, the analytical results showed concentrations of TPH, PAH, chlorinated organic pesticides and volatile chlorinated hydrocarbons such as tetrachlorethylene and vinyl chloride, the latter specifically in water.en
dc.description.uriTrabajo de suficiencia profesionales
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherUniversidad Nacional de Ingenieríaes
dc.rightsinfo:eu-repo/semantics/restrictedAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es
dc.sourceUniversidad Nacional de Ingenieríaes
dc.sourceRepositorio Institucional - UNIes
dc.subjectRemediación ambientales
dc.subjectSubsueloses
dc.titleCaracterización medioambiental del subsuelo de una instalación industriales
dc.typeinfo:eu-repo/semantics/reportes
thesis.degree.nameIngeniero Geólogoes
thesis.degree.grantorUniversidad Nacional de Ingeniería. Facultad de Ingeniería Geológica, Minera y Metalúrgicaes
thesis.degree.levelTítulo Profesionales
thesis.degree.disciplineIngeniería Geológicaes
thesis.degree.programIngenieríaes
Aparece en las colecciones: Ingeniería Geológica

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
martinez_ae.pdf4,72 MBAdobe PDFVisualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI