Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.14076/9684
Title: Caracterización medioambiental del subsuelo de una instalación industrial
Authors: Martínez Aguirre, Elva María
Advisors: Mendoza Apolaya, Atilio
Keywords: Remediación ambiental;Subsuelos
Issue Date: 2014
Publisher: Universidad Nacional de Ingeniería
Abstract: El presente estudio corresponde a la caracterización medioambiental del subsuelo de una instalación industrial además de considerar la eventual propuesta de actuaciones correctivas (remediación) en caso de obtener alguna afección. La instalación, objeto de estudio, está ubicada en una zona industrial de la provincia constitucional del Callao y se encuentra operando desde hace 20 años. Geológicamente, se sitúa sobre materiales cuaternarios recientes que forman parte del último tramo del cono deyectivo del río Rímac. El nivel de agua subterránea se encuentra a 3,5 metros de profundidad. Para determinar la caracterización se realizaron trabajos de campo, gabinete y laboratorio, estructurados en dos fases: En la Fase I se realizaron trabajos de gabinete como investigación bibliográfica y en la Fase II se realizaron labores de campo que consistió básicamente en la interpretación hidrogeológica con la ejecución de 6 sondeos de 8 metros de profundidad con la instalación de piezómetros en cada uno de ellos y la toma de muestras de suelo y agua para su respectivo análisis. A las muestras de suelo y agua se le realizaron analíticas como cantidad de metales, TPH (Hidrocarburos Totales de Petróleo), PAH’s (Compuestos Aromáticos Policíclicos), pesticidas orgánicos clorados entre otros. Para la valoración de los resultados analíticos obtenidos en suelo, se tomaron como referencia legislaciones europeas, (Legislación española, estándares de calidad del Real Decreto 9/2005 del 14 de enero y Legislación Canadiense, Canadian Environmental Quality Guidelines-CEQG), debido a que en la fecha de la realización del estudio aún no se contaba con ninguna legislación ambiental peruana para suelos. Para valorar los resultados analíticos obtenidos en aguas subterráneas, se utilizaron los Estándares Nacionales de Calidad Ambiental para Agua, Decreto Supremo Nº 002-2008-MINAM. Como era de esperar, según los antecedentes analizados, los resultados analíticos mostraron concentraciones de TPH, PAH, pesticidas orgánicos clorados e hidrocarburos clorados volátiles, como tetracloroetileno y cloruro de vinilo, este último específicamente en agua.
The purpose of the present study was to characterize the subsurface environment at an industrial facility. In addition to considering the characterization, the present study also take into account corrective actions (remediations) in case to get any environmental risks. The industrial facility is located in an industrial area of the Constitutional Province of Callao and it has been operating for 20 years. Geologically, it is situated on recent quaternary materials that are part of the final installment of the Rimac river alluvial cone. The groundwater level is 3.5 meters deep. Field, office and laboratory works were conducted in order to determine the characterization. The characterization was carried out in two phases. In the first phase, office work as library research was performed. In the second phase, field work that was basically the hydrogeological interpretation was performed. The hydrogeological interpretation was carried out using 6 drilling. Each drilling reach 8 meters deep. In each drilling piezometers were installed. In addition, soil and water samples were collected for the respective analysis. A soil sample and water was performed analysis of certain parameters such as amount of metals, TPH (Totals Petroleum Hydrocarbons), PAH's (Polycyclic Aromatic Compounds), chlorinated organic pesticides among others. To evaluate the analytical results of soil were taken as reference European legislation (Spanish legislation, quality standards of Royal Decree 9/2005 of 14 January and Canadian Legislation, Canadian Environmental Quality Guidelines-CEQG) due to on the date of the study is not yet had any Peruvian environmental legislation related to soils. To assess the analytical results of groundwater, the National Environmental Quality Standards for Water, Supreme Decree No. 002-2008-MINAM were used. As expected, based on the information analyzed, the analytical results showed concentrations of TPH, PAH, chlorinated organic pesticides and volatile chlorinated hydrocarbons such as tetrachlorethylene and vinyl chloride, the latter specifically in water.
URI: http://hdl.handle.net/20.500.14076/9684
Rights: info:eu-repo/semantics/restrictedAccess
Appears in Collections:Ingeniería Geológica

Files in This Item:
File Description SizeFormat 
martinez_ae.pdf4,72 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons

Indexado por:
Indexado por Scholar Google LaReferencia Concytec BASE renati ROAR ALICIA RepoLatin UNI